Texas Instruments TI-84 PLUS - Graphing Calculator Manual Book page 402

Guidebook
Hide thumbs Also See for TI-84 PLUS - Graphing Calculator:
Table of Contents

Advertisement

Error Type
DIVIDE BY 0
DOMAIN
DUPLICATE
Duplicate Name
EXPIRED
Error in Xmit
ID NOT FOUND
ILLEGAL NEST
INCREMENT
INVALID
Possible Causes and Suggested Remedies
You attempted to divide by zero. This error is not returned during graphing.
The TI-84 Plus allows for undefined values on a graph.
You attempted a linear regression with a vertical line.
You specified an argument to a function or instruction outside the valid range.
This error is not returned during graphing. The TI-84 Plus allows for undefined
values on a graph. See Appendix A.
You attempted a logarithmic or power regression with a
or power regression with a
You attempted to compute
You attempted to create a duplicate group name.
A variable you attempted to transmit cannot be transmitted because a variable
with that name already exists in the receiving unit.
You have attempted to run an application with a limited trial period which has
expired.
The TI-84 Plus was unable to transmit an item. Check to see that the cable is
firmly connected to both units and that the receiving unit is in receive mode.
É
You pressed
to break during transmission.
You attempted to perform a backup from a TI.82 to a TI-84 Plus.
You attempted to transfer data (other than
a TI.82.
You attempted to transfer
5:Lists to TI82
using
This error occurs when the SendID command is executed but the proper
graphing calculator ID cannot be found.
You attempted to use an invalid function in an argument to a function, such as
seq(
expression
within
seq(
The increment in
during graphing. The TI-84 Plus allows for undefined values on a graph.
For(
The increment in a
You attempted to reference a variable or use a function where it is not valid.
Yn
For example,
cannot reference
You attempted to reference a variable or function that was transferred from the
TI.82 and is not valid for the TI-84 Plus For example, you may have
transferred
Un
N
1
to the TI-84 Plus from the TI.82 and then tried to reference
it.
Seq
In
mode, you attempted to graph a phase plot without defining both
equations of the phase plot.
Seq
In
mode, you attempted to graph a recursive sequence without having
input the correct number of initial conditions.
Seq
In
mode, you attempted to reference terms other than
You attempted to designate a graph style that is invalid within the current
graph mode.
You attempted to use
xyLine or scatter plot.
Y
L
.
G
Prn(
G
Int(
pmt2
or
with
L1
through
L1
L6
through
from a TI-84 Plus to a TI.82 without
LINK SEND
on the
menu.
seq(
for
.
is 0 or has the wrong sign. This error is not returned
loop is 0.
Y
Xmin
@
X
,
,
Select(
without having selected (turned on) at least one
Appendix B: Reference Information
X
L
or an exponential
pmt1
<
.
L6
) from a TI-84 Plus to
TblStart
, or
.
(n
1)
(n
2)
N
or
N
.
395

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ti-84 plus silv84plseclm1l1tTi-84 plus silver editionTi-84 plus

Table of Contents