Error Type
INVALID DIM
ITERATIONS
LABEL
LINK L1 (or any other
file) to Restore
MEMORY
MemoryFull
MODE
NO SIGN CHNG
NONREAL ANS
OVERFLOW
Possible Causes and Suggested Remedies
ERR:INVALID DIM
•
The
function that does not involve the stat plot features. The error can be corrected
by turning off the stat plots. To turn the stat plots off, press
4:PlotsOff
then select
•
You specified a list dimension as something other than an integer between 1
and 999.
•
You specified a matrix dimension as something other than an integer between
1 and 99.
•
You attempted to invert a matrix that is not square.
solve(
•
The
function or the equation solver has exceeded the maximum
number of permitted iterations. Examine a graph of the function. If the
equation has a solution, change the bounds, or the initial guess, or both.
irr(
•
has exceeded the maximum number of permitted iterations.
æ
•
When computing
, the maximum number of iterations was exceeded.
The label in the Goto instruction is not defined with a Lbl instruction in the
program.
The calculator has been disabled for testing. To restore full functionality, use
TI Connect™
software to download a file to your calculator from your
computer, or transfer any file to your calculator from another TI-84 Plus. (See
the instructions under Important Things to Know about your TI-84 Plus, earlier
in this chapter.)
Memory is insufficient to perform the instruction or function. You must delete
items from memory before executing the instruction or function.
Recursive problems return this error; for example, graphing the equation
Y1=Y1.
Branching out of an If/Then, For(, While, or Repeat loop with a Goto also can
return this error because the End statement that terminates the loop is never
reached.
•
You are unable to transmit an item because the receiving unit's available
memory is insufficient. You may skip the item or exit receive mode.
•
During a memory backup, the receiving unit's available memory is insufficient
to receive all items in the sending unit's memory. A message indicates the
number of bytes the sending unit must delete to do the memory backup.
Delete items and try again.
You attempted to store to a window variable in another graphing mode or to
perform an instruction while in the wrong mode; for example, DrawInv in a
graphing mode other than Func.
solve(
•
The
function or the equation solver did not detect a sign change.
•
You attempted to compute
Ú...
FV
PMT
when
, (
), and
•
You attempted to compute
CFList
CFO
neither
nor
In Real mode, the result of a calculation yielded a complex result. This error is
not returned during graphing. The TI-84 Plus allows for undefined values on a
graph.
You attempted to enter, or you have calculated, a number that is beyond the
range of the graphing calculator. This error is not returned during graphing.
The TI-84 Plus allows for undefined values on a graph.
error message may occur if you are trying to graph a
.
æ
Ú...
FV
PMT
when
, (
PV
are all
_
0.
irr(
CFList
when neither
is < 0.
Appendix B: Reference Information
y ,
and
PV
‚
), and
are all
0, or
CFO
nor
is > 0, or when
396