3. Change your baud rate to 115200 bps, and press Enter to
enable download mode. From the terminal emulation program,
select the file you want to download, set the protocol to
XModem, and then initialize downloading.
Notes: 1. If you use Windows HyperTerminal, disconnect and
reconnect to enable the new baud rate.
2. The download file should be an SMC8608SX binary file
from SMC; otherwise the agent will not accept it. The
file naming convention is:
Runtime program:
POST program:
Mainboard program: 8051-Vx.yz
4. After the file has been downloaded, the console screen will
display information similar to that shown below. Press "s" to
start the management interface, change the baudrate back to
19200, and press Enter. The Logon screen will then appear.
XMod em Dow nload to D RAM b uffer area 0x002 00000 :
Veri fying image in D RAM d ownlo ad bu ffer 0 x0020 0000. .. SU CCESS !
Upda te Fla shROM Imag e at 0x028 80000 ... S UCCES S !
(D)o wnload anot her I mage or (S )tart Appli catio n: [S ] s
Chan ge Bau d Rat e to 19200 and Press <ENTE R>.
For details on managing the switch, refer to Chapter 2 for
information on the out-of-band console interface, or Chapter 3 for
information on the Web interface.
Agent-Vx.yz,
Boot-Vx.yx, and
T
ROUBLESHOOT ING
.. . SUC CESS !
A-3