Appendix E Error Codes - Datamax PE Operator's Manual

Pe series
Table of Contents

Advertisement

Error Codes
The most common error codes transmitted by the Printer are
described below.
Lower case "c"
Lower case "e"
Lower case "v"
Upper case "I"
Upper case "R"
Upper case "T"
BELL HEX "07"
PE Series Operator's Manual
Appendix E
Printer received a data byte from the host that contains a
framing error (corrupted) due to noise.
Memory module won't clear. Retry after a <STX> W
command.
Input buffer overflow.
This means that an invalid command sequence was sent to
the Printer. The Printer did not understand the command
sequence and terminated the command interpreter.
This code will be sent every time the Printer is turned on,
this means there was a hardware reset.
This means that the Printer has had a watchdog time-out
condition. This is how a software reset occurs. A software
reset is made by sending the command sequence to the
Printer or by doing a front panel reset.
This is usually returned on a corrupt image download, or if
you try to load an image that is already installed in the
module.
E-1