Datamax PE Operator's Manual page 47

Pe series
Table of Contents

Advertisement

Pqfsbujpo
(CONT.)
Test Mode
*Disable
Enable
Cutter
Enable
*Disable
Ribbon Saver
Enable
*Disable
Conversion
*Decimal
Metric
Dpnnvojdbujpot
Comm Setup
*PORTA
*9600
*8 *N *1 *BOTH
Control Codes
*Standard Codes
Alternate Codes
PE Series Operator's Manual
Causes the printer to send debug characters back to
the host. See Appendix E for listings.
Controls an external cutter mechanism.
Enables an external cutter.
Cutter not being used.
Controls the optional Ribbon Saver feature.
Enables the option.
Option is not installed or disabled.
Sets standard or metric measurement, automatically
updating all operations with the new selection.
Measurements in inches
Measurements in millimeters
Allows the user to select communication values for
each port.
Selects the port and sets parameters.
Selects serial Port A, B or Parallel communication.
Selectable serial baud rates: 300, 600, 1200, 2400,
4800, 9600, 19200.
Sets word length: 7 or 8 bits.
Sets parity bit: E = even, O = odd, N = none.
Sets stop bit length: 1 or 2 bits.
Selects handshaking method: XON/XOFF,
CTS/DTR or BOTH.
Sets the DPL control code values.
01 Hex = SOH command, 02 Hex = STX command
5E Hex = SOH command, 7E Hex = STX command
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pe42Pe43

Table of Contents