Advanced Entry Calibration (continued)
Step
Operator Action
12 From the data collected in
Steps 10 and 11, where
both the sensor readings are
above 20, subtract each
Label Value from the
corresponding TOF Value.
These are the Difference
Values.
From the resulting list, find
the largest Difference
Value (see example below).
Its associated Gain Number
will provide the best
algorithm for your media.
For example, if your
compiled data had the
values shown in this
table, Gain Number 8
would be chosen
because it has the
highest Difference
Value (146) where
both the Label Value
and the TOF Value
are above 20.
74
Displayed Message
HBJO!USBO!!!!!!=zzz?
+11!!!!!!!!!)1!.!42*
Or, for reflective media:
HBJO!SFGM!!!!!!=zzz?
+11!!!!!!!!!)1!.!42*
Gain
Label
Number
Value
00
255
01
251
02
241
03
231
04
219
05
212
06
200
07
189
08
178
09
167
10
156
11
146
12
136
...
...
31
116
32
112
Comme nt
Both sensor
readings must
be above 20.
TOF
Difference
Value
Value
254
1
240
11
213
28
182
49
150
69
119
93
88
112
58
131
32
146
19
N/A
17
N/A
16
N/A
15
N/A
...
...
14
N/A
14
N/A