RPS LED

Figure 1-8
RPS LED on the Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, 2924M XL, and
2924M XL DC Switches
Color
RPS Status
Off
RPS is off or is not installed.
Green
RPS is operational.
Blinking green
The RPS and the switch AC power supply are both powered up. If the switch power
supply fails, the switch powers down and after 15 seconds restarts, using power
from the RPS. The switch goes through its normal boot sequence when it restarts.
Note
Amber
RPS is connected but not functioning.
Table 1-3
RPS LED on the Catalyst 2912 LRE XL and 2924 LRE XL Switches
Color
RPS Status
Off
RPS is off or not properly connected.
Solid green
RPS is connected and ready to provide back-up power, if required.
Blinking green
RPS is connected but is unavailable because it is providing power to another device
(redundancy has been allocated to a neighboring device).
78-6461-04
The Catalyst 2912 LRE XL and Catalyst 2924 LRE XL switches use the Cisco
RPS 300 (model PWR300-AC-RPS-N1). All other Catalyst 2900 XL and
Catalyst 3500 XL switches use the Cisco RPS 600 (model PWR600-AC-RPS).
Refer to the appropriate switch documentation for redundant power system (RPS)
descriptions specific for the switch.
colors and their meanings.
This is not a recommended configuration. For more information see the
"Cisco RPS Connector" section on page
The RPS could be in standby mode. Pressing the Mode button on the RPS puts
it in Ready mode, and the LED should turn green.
One of the power supplies in the RPS could have failed.
The fan in the RPS might have failed.
Table 1-2
and
1-22.
Catalyst 2900 Series XL Hardware Installation Guide
Front-Panel Description
Table 1-3
list the RPS LED
1-13