Extreme Networks Alpine 3802 Hardware Installation Manual page 324

Consolidated “i” and “e” series
Hide thumbs Also See for Alpine 3802:
Table of Contents

Advertisement

Switch Technical Specifications
Table 74: Summit 300-48 internal power supply electrical specifications (continued)
Environmental Operating Conditions
Operating Temperature
Storage Temperature
Operating Humidity
Operational Shock
Standards
Table 75 lists the environmental and safety specifications for the Summit 300-48 power supply.
Table 75: Summit 300-48 internal power supply environmental and safety specifications
Safety
Agency Certifications and
Standards
324
0° to 40° C (32° to 104° F)
-40° to 70° C (-40° to 158° F)
10% to 95% relative humidity, noncondensing
30 m/s2 (3g)
EN/ETSI 300 019-2-1 v2.1.2 – Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 – Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 – Class 3.1e Operational
EN/ETSI 300 753 (1997-10) – Acoustic Noise
ASTM D5276 Drop Packaged
ASTM D3580 Random Vibration Packaged 1.5G
North American Safety of ITE
• UL60950 3rd Edition, Listed Device
• CSA 22.2#60950-00
• NOM/NYCE (Mexico Safety)
European Safety of ITE
• EN60950:2000+All Available Country Deviations
• 73/23/EEC Low Voltage Directive
International Safety of ITE
• CB Scheme IEC 60950:1999+All Country Deviations
• AS/NZX 3260 (Australia /New Zealand)
• GOST (Russia)
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide