Troubleshooting Diagnostic Commands
If a data connection could not be established, you might be able to
determine the cause through the AT command interface.
Follow the steps listed below:
• Close all data applications.
Otherwise, these applications might start a retry command that will
interrupt your troubleshooting efforts.
• Unplug and re-connect the data cable.
This terminates any ongoing data connections.
• Establish basic computer-to-modem communication.
For instructions, see "Establishing Communication" on page 72.
• Query the last "Extended Error Code".
Although you might not be able to see the text as you type it, you should
see a result code returned to you.
AT Command
Command Syntax
Expected Return Code(s)
Extended Error Result Codes
Extended error result codes report the network reason why a data
connection failed. If you report a failed connection to technical support, be
sure to provide the code. See the following table for a list of the extended
error result codes that the modem can return.
Table 4: Extended Error Result Codes
Code
Description
General Modem Operation
257
No further information is available.
259
A command was issued during an improper state
(Command/Online).
260
The connection was aborted by the user.
261
The DCE does not recognize an AT Command.
262
The connection was aborted due to a connection timeout.
263
The parameters for an AT Command are out of range.
16A
The +FCLASS command failed due to incompatibilities
with the current setting of the +WS46 command.
Return Product Information
AT+ceer
See Below