Reading Controller Information - Omron ZS Command Reference Manual

Smart sensors compoway/f communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

11

Reading Controller Information

Read data about ZS Series types and so on.
Command
MRC
SRC
"05"
"01"
2 bytes 2 bytes
Response
MRC
SRC
Response Code
"05"
"01"
2 bytes 2 bytes
Elements
Response Code
Model
Version
Response code for normal end
Response Code
"0000"
Normal end
Response code when an error occurs
Response Code
"1001"
Long command length
"1002"
Short command length
Model
4 bytes
20 bytes
Indicates controller status for the command. Data to be read is not returned when an
error occurs.
Model is expressed with 20 ASCII characters.
Version is expressed with 20 ASCII characters.
Name
No errors.
Error Name
Command length is too long.
Command length is too short.
CompoWay/F Communication Command Reference

Reading Controller Information

Version
20 bytes
Details
Details
Cause
ZS Series
Section 2
2-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu