Example 2: To set the peak hold mode for the 1CH controller, assign a command as follows:
[Data No.]=02h, [Unit No.]=2Dh, [Machine No.]=01h, [Data to be written]=00000001h
MRC
SRC
02h
02h

Commands and Responses

Command
MRC
SRC
Parameter Type
"02"
"02"
2 bytes 2 bytes
Number of
Data to be written
elements
"8001"
4 bytes
Elements
Parameter Type
Writing start address
Number of elements
Data to be written
Parameter Type
Writing start
address
C002h
2D01
Writing start
address
4 bytes
4 bytes
4 bytes
Specify parameters depending on the data to be written.
List of Parameter Area Writing Commands page 2-6
Specify the Machine No. (=CH No.) of the controller to write data by using an ASCII
code expressed in hexadecimal numbers.
Please note that the format of "processing unit data writing" commands is XXYYh
(XX : <Unit No.>, YY : <Machine No.>)
Unit No. and Parameter No. page 3-4
Specify number of elements depending on the Parameter Type.
List of Parameter Area Writing Commands page 2-6
Data to be written is specified by using an ASCII code in hexadecimal numbers.
Data length varies depending on commands.
• List of Parameter Area Writing Commands page 2-6
• Do not issue commands other than specified parameter types.
Issuing wrong commands may rewrite internal parameters. In the
case that internal parameters of connected sensors are rewritten,
execute "EEPROM initialization" of operation instruction
commands.
Reading Parameter Areas
Number of
elements
8001h
Details
CompoWay/F Communication Command Reference
Section 2
Data to be written
00000001h
2-7
ZS Series