Installation - Omron WLM Datasheet

Long-life two-circuit limit switch
Table of Contents

Advertisement

Accessories
Cable
Straight
5 dia.
5 dia.
AC
DC

Installation

Item
Changing the installation position of
the actuator
By loosening the Allen-head bolt on the
actuator lever, the position of the actua-
tor can be set anywhere within 360 .
With Lamp-equipped Switches, the ac-
tuator lever comes in contact with the
top of the lamp cover, so use caution
when rotating and setting the lever.
Installing the roller on the inside
By installing the roller lever in the oppo-
site direction, the roller can be installed
on the inside. (Set so that operation can
be completed within a 180 level
range.)
Changing the orientation of the head
By removing the screws in the four cor-
ners of the Head, the Head can be set
in any of the four directions. Be sure to
change the plunger for internal opera-
tions at the same time. (The operational
plunger does not need to be changed
on overtravel general-purpose and
overtravel high-sensitivity models.)
Changing the operating direction
By removing the Head on models which
can operate on one-side, and then
changing the direction of the operation-
al plunger, one of three operating direc-
tions can be selected.
The tightening torque for the screws on
the Head is 0.78 to 0.88 N·m.
F-106
Long-life Two-circuit Limit Switch
14.9 dia.
Appropriate model/actuator
Roller Levers: WLMCA2@, WLMH2@,
WLMG2@, WLMGCA2@
Roller Levers: WLMCA2@, WLMH2@,
WLMG2@, WLMGCA2@
Roller Levers: WLMCA2@, WLMH2@,
WLMG2@, WLMGCA2@
Roller Levers: WLMGCA2@
WLM@
6 dia.
Loosen the
Allen head bolt
Loosen the screws
Head
The output of the
Switch will be changed,
regardless of which
direction the lever is
pushed.
Operating
Not operating
Operating
Operation in both
Clockwise operation
directions
Details
Loosen the M5 × 12 bolt, set the
actuator's position and then
tighten the bolt again.
Head
Loosen the
screws
The output of the
Switch will only be
changed when the lever
is pushed in one
direction.
Not operating
Operating
Operating
Operational
plunger
Anti-clockwise
operation

Advertisement