Display window for new sensor settings New settings of E3NT-L
8-2-1-2
Setting switching points
Switching points A to D can be set in the Switching distances box.
Actuating the key minimum distance the display changed to the maximum
distance. Also in reverse direction.
Switching points B and D and the sliders B and D can only be set if the
mode of the Outputs 1 or 2 has been set to window evaluation.
The Teach buttons C and D are each activated if the Connector pin 2
function has been set to Switching output 2 (see Section 8-2-2-3-1
Pin assignments).
The distance that is currently measured by the sensor is indicated by a
bar graph and as a numeric value under min/max.
The switching points can be set in several ways:
• By means of sliders A to D
The positions of the sliders can be altered by dragging with the mouse.
The resulting set switching distance is displayed under the sliders as a
numeric value for the relevant switching point.
• Number input in the case of Switching distances A to D
When Switching distance is selected, the switching distance of the rele-
vant switching point can be entered as a number. The resulting set
switching distance is set on the relevant slider.
The numeric value can be increased or reduced with the adjacent Incre-
ment and Decrement buttons.