Versatile I/O and Large-capacity
Versatile I/O and Large-capacity
Screen Memory in a Space-saving Size
Screen Memory in a Space-saving Size
Small Size, Large Screen
The LCD screen is larger than the OMRON NT20S
(increased from 256 x 128 dots to 260 x 140 dots), but the
external dimensions and panel cut-out size are the same.
Larger
screen
Two RS-232C Ports
Two RS-232C ports in the NT21 (compared with one in the
NT20S) enable simultaneous connection of a PLC, Bar
Code Reader, and NT Support Tool (connectable to serial
port A only).
NT Support Tool
(screen creation/transfer)
RS-232C
RS-232C
PLC (host)
Plenty of Capacity for Saving Graphic Screens
With 512 Kbytes of memory
capacity, there is more than
ample space for storing screen
data.
Abundant
graphic screen
storage
Versatile Communications
In addition to the Host Link and 1:1 NT Link
communications, the NT21 supports high-speed 1:N NT
Links and Memory Link communications.
NT21
NT21
RS-232C
RS-232C
Memory
PLC (host)
Link
High-speed
1:N NT Links
4
Highly Reliable Hardware
Highly Reliable Hardware
Long, Maintenance-Free Life (50,000 h)
Conforms to International Standards
The NT21 conforms to the EC Directives, as well as UL,
cULus (Class 1 Div2), and C-Tick.
The front panel has an enclosure rating equivalent to IP65F.
System and screen data can be stored in
NT21 Flash Memory.
Function Support Equivalent to That
Function Support Equivalent to That
of a Mid-size Operator Interface
of a Mid-size Operator Interface
Recipe Function
Parts tables on the PT
screen can be used to set
NT21
multiple word data in
records, which can then
be written to the PLC by a
simple PT touch panel operation. For example, the setting
parameters for separate models can be edited on the PT,
then written to or read from the PLC.
Alarm List/History(*)
An alarm message can be
displayed in response to
PLC bit status, and the
content and time of the
message can be stored as
*C500-BAT08 Battery
(sold separately) required.
an alarm history.
Programming Console Function
The NT21 is equipped with many of the same functions as
the SYSMAC PLC Programming Console.
NT21
Programming Console
function
RS-232C
Mathematical Functions
Up to 256 math equations can be stored in the PT
Personal
processing table to allow automatic PT processing, and
computer
the results can be written to the numeral memory table or
(host)
other destinations. This makes it possible to perform
scaling and other mathematical operations automatically
in the PT.
Upgraded NT Support Tool Version (-
Upgraded NT Support Tool Version (-
Enhanced Editing Functions
•I/O comments in the I/O tables of the CX-Programmer can
be used directly.
I/O comments for designated PLC addresses can be
used directly, with no need for CSV file conversion.
Comparison with the NT11
Model
Basic
Dimensions
performance
Resolution
Effective display area
Display color
Panel cut-out size (W x H)
Max. number of
registered screens
Screen data capacity
Function keys
Other Keys
Display
Rectangles, polygons,
elements
arcs, sectors
Painting out
Image/library displays
Analog meters
Trend graphs
Broken line graphs
Alarm lists/histories
Recipes
Special
Interlocks
functions
PLC (host)
Mathematical
Function
Programming
Console function
High-quality font
Memory Unit
Backlight service life
Communications
Memory Links
Bar Code Reader
connection
Host Link Speed
*
Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.
EV4.7)
EV4.7)
•Symbol Manager previews
are supported.
This function makes it
possible to preview symbols
NT Support Tool
CX-Programmer
(parts created from graphics
data).
CX-Server
•Parts can be copied by drag &
I/O comment data
drop operations of image,
library, or mark data.
•The properties of grouped
parts can be edited without
having to ungroup them.
•Because NT20S and NT31
screen data is compatible
with the NT21, existing software assets can be utilized
to greatly reduce the number of design steps.
Note: Some data revisions may be required due to size differences.
•Windows XP supported.
NT11
NT11S
218 x 113 x 38.2 mm (H x W x D)
160 x 64 dots (4.24 inches)
100 x 40 mm
Black & white (with Yellow mode)
204.2 x 99.8 mm
250
32 KB
4
Numeric Keys, Cursor Keys, Function Keys
None
None
None
None
None
None
None
None
None
None
None
None
None (Emergency transfer mode)*
50,000 hours min.
10,000 hours min.
None
None
Up to 115,200
9,600/19,200
NT21
NT20S
190 x 110 x 53.5 mm (H x W x D)
260 x 140 dots
256 x 128 dots
(5.2 inches)
(4.91 inches)
117 x 63 mm
112 x 56 mm
Black & white (with blue mode)
178.5 x 100.5 mm
3,999
500
512 KB
96 KB
None
None
None
None
Supported
None
Supported
None
256 positions per screen
None
50 positions per screen
None
1 position per screen
None
1 position per screen
None
4 positions per screen
None
1 position per screen
None
Supported
None
Math equations: Max. 256
(arithmetic functions,
logic operations,
None
bit manipulations,
comparison operations)
(Executes functions
equivalent to C200H-PR027
None
and CS1 Programming
Consoles.)
Supported
None
Supported
None
50,000 hours min.
10,000 hours min.
Via RS-232C
Supported
communications
Supported
None
9,600/19,200
9,600/19,200
5