Special Cable Specifications
1-3-4

Removable Box Cable

No.
Circuit
symbol
1
CN1
2
CN1
3
CN2
4
CN2
5
CN3
6
CN3
7
8
9
10
11
CN4
12
CN4
13
14
15
Wiring Hard-wired Signals
The function keys and the emergency stop switch are connected through the
Removable Box connected via the Removable Box Cable and output to safety
circuits or other circuits connected to the hard-wired terminal block.
Wiring the Serial Communications Line
There is only one type of RS-232C connector. It is a 37-pin male D-Sub con-
nector and can be directly connected to the RS-232C port on the NSH5-
AL001 Removable Box.
Cable Dimensions
NSH5-232CN-3M/10M
CN1
80
±10
1
2
CN2
7L30 dia.
3
4
(30)
CN3
5
6
70
±10
Product name
Housing
Crimp Terminal
Housing
Crimp Terminal
Housing
Crimp Terminal
Heat-shrinkable
Tube
Packing
Housing
Cable
D-SUB37P Plug
D-SUB37P Hood
Cable
Label
Jack Screw
(30)
8
9
7
L
Model
DF3-3S-2C
DF3-2428SCFC
SHDR-20V-S-B
SSH-003GA-P0.2
DF11-18DS-2C
DF11-2428SCFA
SUMITUBE F2 (Z), 14-mm dia.,
black
GMP-20
BS-M20 × 1.5
2464 composite, 27-conductor,
shield
XM2A3701
XM2A3711
UL1061AWG28 yellow
NSH5-232CN-3M·LOT No.
XM2Z-0071
Section 1-3
14
11
12 15
7
10
10
±5
Maker
Quantity
Unit
HRS
1
Pieces
HRS
3
Pieces
JST
1
Pieces
JST
8
Pieces
HRS
1
Pieces
HRS
18
Pieces
Sumitomo
0.06
m
LAPP
1
Pieces
LAPP
1
Pieces
Bando Elec-
L
m
tric Wire
OMRON
1
Pieces
OMRON
1
Pieces
Kyowa Elec-
0.06
m
tronic
Instruments
1
Pieces
OMRON
2
Pieces
CN4