Recommended Enabling Circuits
Block Diagram When an SNC Unit Is Used
Emergency
stop switch
Enabling
switch
NSH5 Hand-held PT
E1, E2: 24-VDC power supply
S1, S2: Reset switch
KM1, KM2: Contactor
V1/G1, V2/G2, I0 to I15, O0 to O7, T0 to T1: NE1A terminals. Connect a 24-VDC power supply to the V0/G0
power supply terminals for the NE1A internal circuit.
I0
I4
I2
I1
I3
I5
Key switch
z
G1
T0
V1
V2
G2
T1
E2
E1
I8
I12
I6
I10
I14
I7
I9
I11
I13
I15
Door switch
Reset switch
z
T2
O0
O2
O4
O6
T3
O1
O3
O5
O7
Lamp
KM2
Appendix E
KM1-NC
KM2-NC
KM1
KM2
KM1
M
83