Test Run Checklist; Test Run Checklist - Omron J1000 User Manual

J1000 series compact general purpose inverter
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

4.9

Test Run Checklist

Review the checklist before performing a test run. Check each item that applies.
No.
1
Thoroughly read the manual before performing a test run.
2
Turn the power on.
3
Set the voltage for the power supply to E1-01.
Check the items that correspond to the control mode being used.
WARNING! Ensure start/stop and safety circuits are wired properly and in the correct state before energizing the drive. Failure to comply
could result in death or serious injury from moving equipment. When programmed for 3-Wire control, a momentary closure on terminal
S1 may cause the drive to start.
No.
4
The
To give a run command and frequency reference from the LED Digital Operator, press
5
The LO/RE key lights while LOCAL is displayed.
If the motor rotates in the opposite direction during the test run, switch two of the drive output terminals (U/
6
T1, V/T2, W/T3).
7
Select the correct duty rating (C6-01) for the application.
Set the correct values for the motor rated current (E2-01) and the motor protection selection (L1-01) to ensure
8
motor thermal protection.
If the run command and frequency reference are provided via the control circuit terminals, set the drive for
9
REMOTE and be sure the LO/RE light is out.
If the control circuit terminals should supply the frequency reference, select the correct voltage input signal
10
level (0 to 10 V) or the correct current input signal level (4 to 20 mA or 0 to 20 mA).
11
Set the proper voltage to terminal A1. (0 to 10 V).
12
When current input is used, switch the drive built-in DIP switch S1 from the V-side (OFF) to I-side (ON).
Set the minimum and maximum frequency references to the desired values. Make the following adjustments
if the drive does not operate as expected:
Gain adjustment: Set the maximum voltage/current signal and adjust the analog input gain (H3-03) until the
13
frequency reference value reaches the desired value.
Bias adjustment: Set the minimum voltage/current signal and adjust the analog input bias (H3-04) until the
frequency reference value reaches the desired minimum value.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
should illuminate after giving a run command.
Checklist
Checklist

4.9 Test Run Checklist

Page
63
86
Page
to set to LOCAL.
60
63
60
60
72
67
4