F3sp-u5p-tgr series single beam safety control unit safety level 4
Hide thumbs Also See for F3SP-U5P-TGR:
Table of Contents

Advertisement

F3SP-U5P-TGR

12 TECHNICAL DATA.

• Voltage: 24 Vdc ± 10%
• Electrical input: 420 mA max (for any model)
• Combinable photocells: OMRON E3FS series and
• Number of photocells: four pairs max
• Wire range: size AWG 14 – 24 Solid/Stranded
• Wire type: 60/75 °C copper (Cu) conductor only
• Torque on terminals: 2.0 N*m
• Indicators: 4 green LEDs, 1 green/red LED
• Response time: ≤ 30 ms
• Working temperature: -10 a + 55 °C
• Humidity: from 15% to 95% (not condensing)
• Output contacts: 2 NO, 250 Vac 2.5 A max
• Switch capability: 1,500 VA, 180W
• Electrical life expectance: 100.000 op. minimun at 1,800 oprs/hr.
• Operative distance: according to the type of photocell
• Outer controls: start/restart control, test, muting
• Housing: plastic case for installation on a din/omega rail
• Protection class of control unit: IP 20
• Protection class of photocells: IP 67
• Protection class of the cabinet containig the control-unit: IP54 at least
• Weight: control unit 600 g
• Features of fuses muting signalling lamp: internal resettable fuse
315mA T 60V
• Muting signalling: F39-A11