Omron F3SP-U5P-TGR User Manual page 21

F3sp-u5p-tgr series single beam safety control unit safety level 4
Hide thumbs Also See for F3SP-U5P-TGR:
Table of Contents

Advertisement

F3SP-U5P-TGR
where:
D:
d
:
1
Application with four muting sensors and only photocell S1:
minimum distance that the muting sensors keep active the
request; it depends on the parcel length: D < L.
necessary maximum distance so that the muting request is
accepted; it depends on the parcel speed:
This distance must not allow to activate both sensors and
the muting with the accidental passage of a person.
Muting
signalizer
Start & Test
button
F3SP-U5P-TGR
control-unit
Protect the
cables
d
[cm]= v[m/s] * 3[s] * 100
max
Light cable
Power cable
Muting cable
RX cable
TX cable
User's manual