F3SP-U4P-TGR
12

TECHNICAL DATA.

• The control unit can be used with all safety light curtains listed 11.1
Note that all safety light curtains to be used are certified according with the
EN61496-1 Type 4/ Type 2
• Electrical input: 420 mA max. (for any model).
• Voltage: 24 Vdc ± 10%.
• Number of light curtains: 2 pairs max.
• Indicators: 5 green LEDs, 1 red LED.
• Response time: <= 18 ms
• Working temperature: -10 a + 55 °C.
• Humidity: from 15% to 95% (not condensing).
• Output contacts: 2 NO, 2.5 A max, 250 Vac, cosϕ 0.6 ÷1
• Switch capability: 1,500 VA, 180W
• Electrical life expectance: 100.000 op. minimun at 1,800 oprs/hr.
• Outer controls: test, reset, muting and override.
• Housing: plastic case for installation on a din/omega rail
• Protection class of control unit: IP 20.
• Protection class of the cabinet containing the control-unit: IP54 at least.
• Weight: control unit 600 g.
• Features of fuses muting lamp: internal resettable fuse 315mA T 250V.
• Muting lamp: F39-A11 incandescent lamp 24 V, 3 W min, 300 mA max.
User's manual