Technical Data - Omron F3SP-U3P-TGR User Manual

F3sp-u3p-tgr series single beam safety control unit safety level 2
Hide thumbs Also See for F3SP-U3P-TGR:
Table of Contents

Advertisement

F3SP-U3P-TGR

12 TECHNICAL DATA.

• Voltage: 24 Vdc ± 10%
• Electrical input: 420 mA max.
• Combinable photocells:
OMRON E3FS series and
Techno GR S5 – S10 – S30 series
• Number of photocells: two pairs max
• Wire range: size AWG 16 – 24 Solid/Stranded
• Wire type: 60/75 °C copper (Cu) conductor only
• Torque on terminals: 0.9 N*m
• Indicators: 5 green LEDs, 1 red LED
• Response time: ≤ 30 ms
• Working temperature: -10 a + 55 °C
• Moisture: from 15% to 95% (not condensing)
• Output contacts: 2 NO, 115 Vac 2.5 A max
• Switch capability: 1,500 VA, 180W
• Electrical life expectance: 100.000 op. minimun at 1,800 oprs/hr.
• Operative distance: according to the type of photocell
E3FS 10m
S5-5
S5-10 8m
S30-5 50m
• Outer controls: start control, test, muting and override
• Housing: plastic case for installation on a din/omega guide
• Protection class of control unit: IP 20
• Protection class of photocells: IP 67
• Protection class of the cabinet containing the control-unit: IP54 at least
• Weight: control unit: 300 g
• Features of fuses muting signalling lamp: internal re-settable fuse
315mA 60V
• Muting signalling: F39-A11
8m
User's manual
25