Characteristics
Degree of protection (see note 1)
Durability (see note 2)
Operating speed
Contact gap
Operating frequency
Direct opening force (see note 4)
Direct opening travel (see note 4)
Insulation resistance
Minimum applicable load (see note 5)
Contact resistance
Dielectric strength
Conditional short-circuit current
Pollution degree (operating environment)
Conventional free air thermal current (I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Cable
Weight
Note: 1. The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing
performance under the actual operating environment and conditions.
Although the switch box is protected from dust, oil, or water penetration, do not use the D4GS-N in places where dust, oil, water, or chem-
icals may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
2. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.
3. When the ambient temperature is 35°C or higher, do not apply 1 A at 125 VAC to more than one circuit.
4. These figures are minimum requirements for safe operation.
5. The value given for minimum applicable load is a reference value for micro-loads. The value will vary depending on factors such as the
switching frequency, the ambient environment, and the reliability level. Be sure to confirm correct operation with the actual load before
application.
G-166
Body: IP67 (EN60947-5-1) (Operation Key insertion face: IP00)
Mechanical:1,000,000 times min.
Electrical:100,000 times min. (1-A resistive load at 125 VAC) (see note 3)
0.1 to 0.5 m/s
2 x 2 mm min.
30 operations/minute
60 N min.
10 mm min.
100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals
of different polarities, and between each terminal and non-current carrying metal parts
4 mA at 24 VDC
300 mΩ max. (Initial value with 1-m cable)
Between terminals of same polarities: Uimp 2.5 kV (EN60947-5-1)
Between terminals of different polarities: Uimp 4 kV (EN60947-5-1)
Between each terminal and non-current carrying metal parts: Uimp 6 kV (EN60947-5-1)
100 A (EN60947-5-1)
3 (EN60947-5-1)
)
2.5 A (EN60947-5-1)
th
Class II (double insulation) (IEC60536)
Malfunction:10 to 55 Hz, 0.35-mm single amplitude
Malfunction:300 m/s
Operating:-30°C to 70°C (with no icing)
Operating:95% max.
UL2464 No. 22 AWG, finishing O.D.: 7.2 mm
Approx. 120 g (D4GS-N1R, with 1-m cable)