Contact Form (Diagrams Show State with Key Inserted)
Model
D4GS-N1#-#
1NC/1NO
D4GS-N2#-#
2NC
D4GS-N3#-#
2NC/1NO
D4GS-N4#-#
3NC
D4GS-N
Contact
Operation Key
insertion comple-
tion position
Operation Key
insertion comple-
tion position
Operation Key
insertion comple-
tion position
Operation Key
insertion comple-
tion position
Diagram
ON
Stroke
Extraction
completion
position
ON
Stroke
Extraction
completion
position
ON
Stroke
Extraction
completion
position
ON
Stroke
Extraction
completion
position
Remarks
Only NC contact 11-12 has an
approved direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
NC contacts 11-12 and 31-32
have an approved direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
Only NC contacts 11-12 and 21-
22 have an approved direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike
poles.
NC contacts 11-12, 21-22
and 31-32 have an approved
direct opening mechanism.
The terminals 11-12, 21-22 and
31-32 can be used as unlike
poles.