Omron ACCURAX G5 SERVO DRIVE Datasheet page 8

Servo drive
Hide thumbs Also See for ACCURAX G5 SERVO DRIVE:
Table of Contents

Advertisement

I/O signals (CN1) - output signals (for analog/pulse servo drives)
Pin No. Control mode
Signal name
21
Position/
+A
Full close loop
22
-A
48
+B
49
-B
23
+Z
24
-Z
19
Z
25
ZCOM
11
Common
BKIR
10
BKIRCOM
35
READY
34
READYCOM
37
/ALM
36
ALMCOM
39
Speed/torque
TGON
39
Position/
INP1
Full close loop
38
INP1COM
-
-
INP2
P-CMD
ZSP
WARN1
WARN2
ALM-ATB
VCMP
V-CMD
V-LIMIT
T-LIMIT
Encoder connector (CN2) - (for all servo drives)
Pin No.
Signal name
1
E5V
2
E0V
3
BAT+
4
BAT–
5
PS+
6
PS–
Shell
FG
External encoder connector (CN4) - (for all servo drives)
Pin No.
Signal name
1
E5V
2
E0V
3
PS
4
/PS
5
EXA
6
/EXA
7
EXB
8
/EXB
9
EXZ
10
/EXZ
Shell
FG
Monitor connector (CN5) - (for all servo drives)
Pin No.
Signal name
1
AM1
2
AM2
3
GND
4
-
5
-
6
-
USB connector (CN7) - (all servo drives)
Pin No.
Signal name
1
VBUS
2
D-
3
D+
4
-
5
GND
68
Function
Encoder phase A+
Encoder signals (or external scale signals during full closing control) are output according En-
coder Dividing Numerator parameter.
Encoder phase A-
This is the line-driver output (equivalent to R422). The maximum output frequency is 4 Mbps.
Encoder phase B+
Phase Z is output for encoder signals (or external scale signals during full closing control). This
Encoder phase B-
is the line-driver output (equivalent to R422).
Encoder phase Z+
Encoder phase Z-
Encoder phase-Z output
Phase Z is output for encoder signals (or external scale signals during full closing control).
Open-collector output.
Encoder phase-Z common
Brake release signal output Timing signal for operating the electromagnetic brake on a motor.
Servo ready: ON if there is not servo alarm when the control/main circuit power supply is turned ON.
Servo alarm: turns OFF when an error is detected.
Motor rotation speed detection. This output turns ON when the motor rotation speed reaches the speed set in a parameter.
Positioning complete output 1: turns ON when position error is equal to setting parameter.
Position complete output 2 The function of output signals allocated to pins 11,10, 34 to 39 can be changed with these op-
tions by parameters settings.
Position command status
Zero speed
Warning 1
Warning 2
Alarm output
Speed conformity output
Speed command status
Speed limit detection
Torque limit detection
Function
Encoder power supply + 5 V
Encoder power supply ground
Battery + (used only with absolute encoder)
Battery – (used only with absolute encoder)
Encoder serial signal input (+phase)
Encoder serial signal input (-phase)
Shield ground
Function
External scale power supply output. Use at 5.2V +/-5% and at or below 250 mA.
This is connected to the control circuit ground connected to connector CN1.
External scale signal I/O (serial signal).
External scale signal input (Phase A, B, and Z signals). Perfoms the input and output of phase A, B and Z signals.
Shield ground
Function
Analog monitor output 1. Outputs the analog signal for the monitor. Use the parameters setting to select the output
to monitor.
Default setting: Motor rotation speed 1 V/(1000 r/min).
Analog monitor output 2. Outputs the analog signal for the monitor. Use the parameters setting to select the output
to monitor.
Default setting: Motor rotation speed 1 V/(1000 r/min).
Ground for analog monitors 1,2.
Terminals not used. Do not connect.
Function
USB signal terminal for computer comunication.
Ground for analog monitors 1,2.
Not used. Do not connect.
Signal ground.
AC servo systems