Omron 2D CODE READER User Manual page 75

2d code reader
Table of Contents

Advertisement

Section 5
Communicating with PC and Programmable Controller
Internal Specifications
Input specifications
Item
Cable model
Input voltage
Input ON current *1
Input ON voltage *1
Input OFF current *2 0.1 mA max.
Input OFF voltage *2 5 V max.
Input ON delay
Input OFF delay
Internal circuit
diagram
*1: ON current/ON voltage
This refers to the current or voltage values needed to shift from the OFF →ON state.
The ON voltage value is the following potential difference.
• NPN type: Potential difference between 24 V terminal and input terminal
• PNP type: Potential difference between input terminal and GND terminal
*2: OFF current/OFF voltage
This refers to the current or voltage values needed to shift from the ON
The OFF voltage value is the following potential difference.
• NPN type: Potential difference between 24 V terminal and input terminal
• PNP type: Potential difference between input terminal and GND terminal
Output specifications
Cable model
Output voltage
Output load current
ON residual voltage
OFF leakage current
Internal circuit
V400-F050/250/350
74
User's Manual
V400-W23/24 (NPN type)
12 to 24V ±10%
5 to 15 mA
7 V min.
RESET: 10 msec max.
TRIG: 0.5 msec max.
RESET: 15 msec max.
TRIG: 0.5 msec max.
24V (Brown)
24 VDC
Input terminal
(TRIG, RESET)
Item
V400-W23/24 (NPN Type)
12 to 24 V ±10%
45 mA max.
1.5 V max.
0.1 mA max.
Specifications
V400-W23P/24P (PNP type)
12 V to
24 V DC
Specifications
V400-W23P/24P (PNP Type)
24 V (Brown)
Load
24 VDC
Output
terminal
GND (Blue)
Input terminal
(TRIG, RESET)
GND (Blue)
OFF state.
24 V (Brown)
Output
24 VDC
terminal
Load
GND (Blue)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V400-fV400-f050V400-f250V400-f350

Table of Contents