Digital Operator - Omron 3G3JV Manual

Simple speed control compact inverters with easy-to-use functions
Hide thumbs Also See for 3G3JV:
Table of Contents

Advertisement

Digital Operator

Data display
Keys
Appearance
Data display
Frequency adjuster
Frequency reference
indicator
Output frequency
indicator
Output current
indicator
Multi-function
monitor indicator
Forward/Reverse
selection indicator
Local/Remote
selection indicator
Parameter setting
indicator
Mode Key
Increment Key
Decrement Key
Enter Key
RUN Key
STOP/RESET Key
Note: 1. The status of the local/remote selection indicator can be only monitored while the Inverter is in operation. Any RUN com-
mand input is ignored while this indicator is lit.
2. While the Inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any
RUN command input is ignored while the parameter setting indicator is lit.
3. For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn
the operation instruction OFF before using this function.
Name
Displays relevant data items, such as frequency reference, output frequency,
and parameter set values.
Sets the frequency reference within a range between 0 Hz and the maximum
frequency.
The frequency reference can be monitored or set while this indicator is lit.
The output frequency of the Inverter can be monitored while this indicator is
lit.
The output current of the Inverter can be monitored while this indicator is lit.
The values set in U01 through U10 are monitored while this indicator is lit.
The direction of rotation can be selected while this indicator is lit when
operating the Inverter with the RUN Key.
The operation of the Inverter through the Digital Operator or according to the
set parameters is selectable while this indicator is lit. (See note 1.)
The parameters in n01 through n79 can be set or monitored while this
indicator is lit. (See note 2.)
Switches the setting and monitor item indicators in sequence.
Parameter being set will be canceled if this key is pressed before entering
the setting.
Increases multi-function monitor numbers, parameter numbers, and
parameter set values.
Decreases multi-function monitor numbers, parameter numbers, and
parameter set values.
Enters multi-function monitor numbers, parameter numbers, and internal
data values after they are set or changed.
Starts the Inverter running when the 3G3JV is in operation with the Digital
Operator.
Stops the Inverter unless parameter n06 is set to disable the STOP Key.
Used to reset the Inverter when an error occurs. (See note 3.)
Nomenclature
Indicators
(Setting/Monitor item
indicators)
FREQ adjuster
Function
7