Gate Operation
Open Button
Opens the gate. If the Controller is programmed to stop opening the
gate at mid-travel, a constant press of the OPEN button will override the
Mid-travel Stop and completely open the gate. If the Auto Close Timer is
set, it will be suspended until the OPEN button is released.
Close Button
Closes the gate if the gate is open. Also closes the gate if the gate is in
the process of opening.
Stop Button
Stops the gate from opening or closing at any time.
Single Input
Opens the gate if it's closed and closes the gate if it's open (open-close
programming option). Activating the input while the gate is moving will
reverse the gate.
Can be programmed to stop the gate while the gate is moving (open-
stop-close programming option).
Fire Department Input
Fully opens the gate when the input is activated. Overrides the Mid-
travel Stop and Auto Close Timer (if either is programmed for the gate).
The gate will lockout in the open position without sounding the alarm.
Press the STOP button to release the lockout.
Open Input
Functions the same as the OPEN button.
Open Obstruction
While the gate is opening, any open obstruction signal will cause the
gate to stop, reverse a short distance, and then stop again. The Auto
Close Timer will be disabled, and a renewed input will be required to
start the gate again. Should the gate be restarted and the obstacle
signal occur again prior to reaching a limit, the gate will stop again,
lockout, and sound the emergency alarm.
Close Obstruction
While the gate is closing, any close obstruction signal will cause the
gate to stop, reverse, and travel to the full open position. Should a open
obstruction input or an open direction inherent entrapment condition
occur prior to the gate reaching the open limit, the operator will lockout
and sound the continuous tone alarm. Another close request will be
required to start the operator again. If after restart, the overload or a
close obstacle happens again before the close limit is reached, the
operator will lockout and sound the alarm. If the auto close timer is set,
when the close obstruction input is cleared, the gate will close when the
auto close timer expires.
HSLG Slide Gate Operator Installation Guide
www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com
Reverse Input
If the reverse input is triggered while the gate is closing, the gate will
reverse to the full open position. If the Auto Close Timer is set, when the
reverse input is cleared, the gate will close when the Auto Close Timer
expires.
Open Loop
Functions the same as the OPEN button.
Reverse Loop
Functions the same as the reverse input.
Shadow/reset Loop
Only used with Swing Gates. Holds the gate fully open or fully closed
while triggered. If open, the gate closes immediately when cleared if
Anti-tailgate is enabled.

Operation Indications

During normal operation, the Controller's displays will indicate current
operating conditions and status.
Power-up Display
When the Controller powers up, dashes will show on the display, then
the firmware version number, then the gate type (SL for slide and swing
gates).
Exiting programming restarts the Controller. The power-up display will
show upon the restart.
Idle Condition
While the Controller is idling, waiting for a command, the display will
show circulating dashes.
Last Gate Position/Condition
When the gate moves or stops, the display will show the status for up
to one minute.
• Stop is displayed as
• Full Close is displayed as
• Full Open is displayed as
• Entrapment is displayed as
Pre-start Delay
During the pre-start delay, the display will countdown the number of
seconds remaining before the operator starts.
Reverse Delay
If the gate travel direction is reversed from a user activation or reversing
device, and a reverse delay is set, the display will count down the delay
time in seconds before the operator restarts.
Run Timer
While the gate is opening or closing, the number of seconds running
time is displayed.