Advanced Controller Programming - Linear HSLG Series Installation Manual

Slide gate operator
Hide thumbs Also See for HSLG Series:
Table of Contents

Advertisement

Advanced Controller Programming

Entering Advanced Programming Mode
To access and program the Advanced Programming functions, for each
programming session, Advanced Programming must be enabled.
After exiting programming, the Advanced Programming functions
will be available on the programming display during the next
programming session unless the operator has run 50 or more
cycles. After that, Advanced Programming must be enabled again.
Maximum Run Time
The factory default for the Maximum Run Time (MRT) is 99 seconds.
When the operator starts, a timer will begin counting. If a open or close
limit is not reached or an obstacle or reversing input is not received
before the timer expires, the operator will stop, the unit locks out and
the alarm sounds. The timer can be set for 10 to 99 seconds, but should
be left at 99 in most applications. Setting it too close to the actual run
time may cause the time to expire with changing ambient temperature,
gate conditions, etc...
If AC is present and an open or close limit is not reached or an obstacle
or reversing input is not received before this timer exceeds MRT, the
operator will stop, the unit locks out and the alarm sounds.
Single Button Input Setup
This function is used for selecting the operation for single button
controls and radio receivers.
The factory default sets the SINGLE input terminal so successive inputs
will cycle the operator in OPEN-STOP-CLOSE-STOP order.
Alternately, the SINGLE input can be set to cause the gate to OPEN
unless the gate is fully open. If the gate is fully open, the input will cause
the gate to CLOSE.
Stagger Mode
(Rarely used in slide gate installations)
This function is used in dual gate installations only. The factory
default sets the Stagger Mode to OFF. In dual gate installations the two
operators communicate through the 3-wire COMM LINK interface.
When using the Stagger Mode, set one operator for delayed opening
and the other operator for delayed closing. The Stagger Delay Time
programming function (see below) sets the length of the delay.
✓ NOTE: This function will only be displayed if dual gate operation
is selected.
Stagger Delay Time
(Rarely used in slide gate installations)
This function is used in dual gate installations only. The factory
default sets the Stagger Time to 0 seconds (OFF). The Stagger Time
sets the delay for the Stagger Mode. The Stagger Time can be set from
1-99 seconds.
✓ NOTE: This function will only be displayed if dual gate operation
is selected.
HSLG Slide Gate Operator Installation Guide
www.LinearGateOpeners.com | (888) 378-1053 | Sales@LinearGateOpeners.com
FUNCTION
"AD"
ADVANCED
PROGRAMMING
FUNCTION
"RT"
MAXIMUM RUN
TIMER
FUNCTION
"SB"
SINGLE BUTTON
INPUT SETUP
FUNCTION
"SM"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
STAGGER
MODE
FUNCTION
"ST"
THROUGH OPTIONS
STAGGER
SELECT AN OPTION
DELAY TIME
- 14 -
OPTIONS
ADVANCED PROGRAMMING FUNCTIONS
WILL NOT BE DISPLAYED
ADVANCED PROGRAMMING OPTIONS
WILL BE DISPLAYED
PRESS UP OR
DOWN TO CYCLE
NOTE: ADVANCED PROGRAMMING
THROUGH OPTIONS
WILL STAY ENABLED AFTER
EXITING PROGRAMMING UNTIL
PRESS ENTER TO
SELECT AN OPTION
THE GATE CYCLES 50 TIMES
OPTIONS
DISPLAY SHOWS CURRENT
MAXIMUM RUN TIME SETTING
ENTER
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP OR DOWN TO CHANGE THE
MAXIMUM RUN TIME (10-99 SECONDS)
ENTER
PRESS ENTER TO STORE THE VALUE
OPTIONS
SINGLE INPUT WILL CYCLE OPERATOR
IN ORDER OF OPEN-STOP-CLOSE-STOP
SINGLE INPUT WILL OPEN OPERATOR,
IF OPERATOR IS ALREADY OPEN, SINGLE
INPUT WILL CLOSE OPERATOR
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
OPTIONS
DISABLES STAGGER FUNCTION
SETS THIS OPERATOR FOR
DELAYED OPEN
SETS THIS OPERATOR FOR
DELAYED CLOSE
OPTIONS
STAGGER TIMER DISABLED
SET STAGGER DELAY VALUE
1 TO 99 SECONDS
PRESS UP OR
DOWN TO CYCLE
PRESS ENTER TO
DUAL GATES
ONLY
DUAL GATES
ONLY
P1220 X14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hslg-443Hslg-123Hslg-111Vs-gslg-111Hslg-421Hslg-411