Performance
Data Sheet
18
Culligan
Important Notice — Read this data sheet and compare the capabilities of the unit to your actual
water treatment needs. Culligan recommends that you have your water supply tested to determine
these needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment system, the more confident
you will be about its performance. It's because of this more than sixty five years of commitment to our
customers that Culligan is providing this Performance Data Sheet to its customers.
Manufacturer Culligan International Company
9399 West Higgins Road, Suite 1100, Rosemont, IL 60018
(847)430-2800
www.culligan.com
Substance Reduction
Model
Substance
10" Iron-Cleer
Iron
12" Iron-Cleer
Iron
* United States Environmental Protection Agency Safe Drinking Water Act
Testing Conditions
Capacity:
1,400 gallons (10" Iron-Cleer)
2,000 gallons (12" Iron-Cleer)
Temperature: 63°F - 73°F
Flow Rate:
5 gpm (10" Iron-Cleer)
7 gpm (12" Iron-Cleer)
pH:
8.0
Operating Conditions
Water Pressure Limits:
20 - 60 psi
Temperature Limits:
33 - 120°F
Electrical Characteristics: 120V/60 Hz 3 Watts continuous
Systems tested and certified by WQA against WQA S-200 for the effective reduction of
iron.
This system has been tested according to NSF/ANSI 42 for the reduction of iron. The concentration of iron in
water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system as specified in NSF/ANSI 42.
Testing was performed under laboratory conditions, actual results may vary.
Performance Indicator: If water flow decreases or a noticeable odor returns, the filter should be reconditioned. If
conditions do not improve, contact your local Culligan Man. He can determine if your filter requires servicing.
Regeneration Frequency: Regeneration frequency will vary depending upon water conditions.
Refer to your Installation and Operation Instructions, Parts List and Printed Warrantees for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed
and serviced by your Culligan Man. Performance may vary based on local water conditions. The substances
reduced by this product are not necessarily in your water.
Buyer Signature
10" and 12" Iron-Cleer
®
USEPA SDWA*
Percent
MCL (MG/L)
Reduction
0.3 mg/L
99%
0.3 mg/L
99%
Pressure:
Acidity:
Rated Pressure Drop @ 5 gpm: 9 psi (10" Iron-Cleer)
Rated Pressure Drop @ 7 gpm: 10 psi (12" Iron-Cleer)
Water Filters
®
Average Influent
Average Effluent
Concentration Level
Concentration Level
9.82 mg/L
9.82 mg/L
60 psi
Non-Corrosive
Date
< 0.1
< 0.1

Advertisement