Culligan Iron-Cleer Plus Owner's Manual page 10

Automatic water filter
Hide thumbs Also See for Iron-Cleer Plus:
Table of Contents

Advertisement

Familiarization
(cont.)
6
Modes of Operation
Manual Regeneration
Pressing and holding the regen button for 3 seconds will initiate an immediate regeneration. The
beeper is to give one beep at the start of manual regeneration (when the motor starts to turn). In
delay mode, pressing and releasing the regen button will light the regen icon for regeneration to
occur at the set delay time. Pressing and releasing the regen button again will turn off the regen
icon.
Power Loss
The AccuSoft
circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The
®
capacitor is capable of maintaining the time, for at least one day, in the event of a power outage.
The EEPROM ensures that the individual programming parameters of your softener are not lost.
If the power outage lasts long
enough to drain the Hi-Cap
Capacitor, the control will flash
"12:00 PM" when power is
returned to the control. The
unit will continue to keep time
from the moment power is
restored, and will initiate a
full regeneration at the preset
regeneration time. The time of
day will need to be reset in
order to return the regeneration
to its preset time.
If you live in an area where
power outages occur with a
regular frequency, a battery
backup option is available for
ensuring that the time of day is
properly maintained. Contact
your Culligan Dealer for more
information.
Display
Back-lit LCD display.
Program Key
Depress to enter and move through the programming steps.
Regeneration
Press and hold the key for three (3) seconds to initiate an immediate regeneration.
Key
When pressed during programming the time of day, this key will allow the user to
toggle between the hours and minutes setting of timing program segments.
Information
Each time depressed, the Information key will display statistical information
Key
such a flow rate, time of day. Use with the Toggle Down key to display other
statistical information.
Toggle
In the programming mode this key will move the user through the programming
Down Key
function in a descending mode. If depressed for greater than three seconds, the rate
at which the display scrolls through data will increase.
Toggle Up
In the programming mode this key will move the user through the programming
Key
function in an ascending mode. If depressed for greater than three seconds, the rate
at which the display scrolls through the data will increase.
This key will also allow the user to manually step through the cycles of regeneration.
Program
Program
Key
Press Regen once to begin regeneration tonight.
Or hold for immediate regeneration.
Toggle
Down
Setting Time Of Day
1. Press Program until 'tod' is displayed.
2. Use arrow keys to adjust minutes.
3. Press Regen once then adjust hours.
4. Continue to press Program to exit menu & save.
Display
Regeneration
Key
Information
Regen
Information
Key
Toggle
Up

Advertisement

Table of Contents
loading

Table of Contents