Performance Data Sheet

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of the unit with
your actual water treatment needs. Culligan recommends that you have your water supply tested to deter-
mine these needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment systems, the more confident you
will be about its performance. It's because of this and more than sixty years of commitment to customer
satisfaction that Culligan is providing this Performance Data Sheet to its customers.
MANUFACTURER:
Culligan International Company,
One Culligan Parkway, Northbrook, IL 60062-6209 USA
(847) 205-6000
PRODUCT: Culligan Good Water Machine Reverse Osmosis Drinking Water System
MODELS:
AC-30
AC-30M
AC-30L
USE GUIDELINES
USE GUIDELINES
USE GUIDELINES
USE GUIDELINES
USE GUIDELINES
Working Pressure: 40-120 psig (280-827 kPa)
Do not allow exposure to temperatures below 33°F (1°C)
Maximum operating temperature: 100°F (38°C)
This system must be installed according to local plumbing codes on the cold water line.
This sytem requires regular replacement of all filters to maintain proper operation. Depending on
usage and influent water quality, the carbon and particulate filters should be changed at least annually
and the reverse osmosis membrane should be replaced every 3-5 years. Varifying chlorine, sediment or
TDS levels may effect replacement frequency.
Particulate Prefilter Element .............................. 00-4015-38
Activated Carbon Prefilter Element ................... 01-0008-27 or 01-0125-80
Activated Carbon Postfilter Element ................. 01-0042-91
Reverse Osmosis Module ................................... 01-0074-02
If water production decreases or a noticeable taste change occurs, contact your local Culligan Dealer.
A Culligan professional can determine if your drinking water system requires servicing. Optional water
quality monitors are also available to monitor the performance of the reverse osmosis membrane.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain filterable cysts. EPA Est 2938-IL-01.
The Good Water Sentry Water Quality Monitor is another way to keep track of your systems
performance. This optional accessory checks your drinking water each time you use the special faucet,
and signals when the membrane filter may need to be replaced.
The AC-30 Nitrate Models are supplied with a nitrate test kit. Product water must be tested frequently
according to the instructions provided with the kit.
SUGGESTED INSTALLATION EQUIPMENT
Sink Cutting Tools
Porcelain Cutter Kit, 1-1/4 inch diameter, PN 00-5916-25
Greenlee Hole Punch, 1-1/4 inch diameter
Plumbers Putty
Heavy Duty Drill with speed control to 400 rpm
AC-30 Plus
AC-30 Nitrate
AC-30M Plus
AC-30M Nitrate
AC-30L Plus
AC-30L Nitrate
Tools
Screwdriver, blade and Phillips (#1)
1/8 inch diameter pilot drill for #10 screws
Center Punch
Razor Blade Knife
Faucet Installation Tool, PN 00-4033-75
Aqua-Cleer H Series or "System" series filter
housing
MSRP
30.00
40.00
20.00
150.00
15