Culligan Medallist Series Installation And Operation Instructions With Parts List

Hide thumbs Also See for Medallist Series:

Advertisement

Cat. No. 01017643
Rev. C 06/04/07
DCO # 10083
Installation
and Operation
Instructions
with Parts List
Culligan Medallist and
®
Medallist Plus Series
Automatic Water Filters
®
®
®
with Cullar
, Cullneu
, or Cullsan
Media
Models from 2006
© 2007 Culligan International Company

Advertisement

Table of Contents
loading

Summary of Contents for Culligan Medallist Series

  • Page 1 Rev. C 06/04/07 DCO # 10083 Installation and Operation Instructions with Parts List Culligan Medallist and ® Medallist Plus Series Automatic Water Filters ® ® ® with Cullar , Cullneu , or Cullsan Media Models from 2006 © 2007 Culligan International Company...
  • Page 2 Culligan equipment. This publication is written specifically for these individuals and is intended for their use. We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by consulting with your Culligan dealer.
  • Page 3: Table Of Contents

    Installation and Operation Instructions with Parts List Culligan Medallist and ® Medallist Plus Series Automatic Water Filters ® ® ® with Cullar , Cullneu , or Cullsan Media Models from 2006 Table of Contents Page Introduction ..........2 Specifications .
  • Page 4: Introduction

    Warning! Electrical shock hazard! Unplug the unit before removing the timer mechanism or coverplates! The Culligan water filter has two separate serial numbers; one for the control assembly and one for the media tank. The control assembly serial number can be found on the left rear side of the timer mounting plate. The media tank serial number is on the side of the tank.
  • Page 5: Specifications

    Specifications and Limitations 8 Inch Medallist 10 Inch Medallist 10 Inch Medallist Plus General Mineral Tank Size 8 x 44 in. 10 x 54 in. 10 x 54 in. Control 3/4” Power Valve 3/4” Power Valve 1” Power Valve Timer Electronic Electronic Electronic...
  • Page 6: Component Description

    Note: The media tank assemblies do not contain filter media, which is shipped separately. See the section on Installation Procedure (Page 10). Bypass Valve ® Includes the Cul-Flo-Valv , interconnecting coupling and screws or clips necessary for assembly. ® Culligan Medallist Series Water Filters...
  • Page 7: Preparation

    In order to size and apply the equipment correctly, a complete analysis of the water supply should be obtained. This can best be accomplished by contacting the local Culligan dealer, who will be able to test the water supply right at the site, or arrange to have one or more water samples sent to the Culligan laboratory for a more detailed analysis.
  • Page 8 (sunlight, rain, wind, heat, cold), contamination, vandalism, etc. as when installed indoors. Figure 2 ® Culligan Medallist Series Water Filters...
  • Page 9 Location Space requirements - Allow 6-12 inches (15-30 cm) behind the unit for plumbing and drain lines. Floor surface - Choose an area with solid, level floor free of bumps or irregularities. Drain facilities - Choose a nearby drain that can handle the rated drain flow (floor drain, sink or stand pipe). Refer to the Drain Line Chart, Table 1 (page 12), for maximum drain line length.
  • Page 10 The Medallist Plus includes a Cul-Flo Valve bypass with 1 1/4” NPT connections. The following optional sweat connection kits are available: Part No. Description 01010783 1” Sweat Copper Adapter Kit 01016564 3/4” Sweat Copper Adapter Kit 01016565 3/4” Elbow Sweat Copper Adapter Kit ® Culligan Medallist Series Water Filters...
  • Page 11: Filling Procedure

    Filling Procedure ® Filtr-Cleer Water Filter The 8” Filtr-Cleer filters are shipped with one media pack and the 10” Filtr- Cleer filters are shipped with two media packs. Verify that the proper number of media packs are on site before loading the tank. Place the manifold inside the tank.
  • Page 12: Installation

    Locate the two U-clamps and screws in the small parts package. Install the clamps on both sides of the control as indicated in figure 7 and secure them with the screws. Figure 6 Figure 7 ® Culligan Medallist Series Water Filters...
  • Page 13 Mount the Control Valve - 1” Controls Assemble the control valve to the media tank as follows, See Figure 8 Assemble the o-rings, located in the parts pack, to the tank adapter. The valve adapter o-ring sits on the first step on the adapter. See Figure 9.
  • Page 14 Replace the drain elbow assembly and secure it with the u-clip. Figure 10 Plumbing Connections - 3/4” Controls Shipped with each softener is a Culligan ® bypass valve, which is used to connect the softener to the plumbing system. The bypass allows the softener to be isolated from the water service line if service is necessary while still providing water to the home.
  • Page 15 Plumbing Connections - 1” Controls ® Shipped with each softener is a Culligan bypass valve, which is used to connect the softener to the plumbing system. The bypass allows the softener to be isolated from the water service line if service is necessary while still providing water to the home.
  • Page 16 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. ® Table 2 - Culligan Automatic Water Filters, 8 Inch Average Height of Drain Discharge Above Floor on Which Filter Sets Water Pressure 4” 1 ft.
  • Page 17: Settings

    Settings Your Culligan Medallist Water Filter is designed to perform efficiently on a wide range of water supplies. Before the unit can be recharged and put into service, several settings must be made. Backwash Backwash expands and loosens the media bed, and flushes away accumulated particulate matter. The backwash interval is preset at the factory for 10 minutes, which is adequate for most water supplies.
  • Page 18 Figure 16 - Circuit Board Display Programming the Option Settings The microprocessor has several programming options that can be changed for various additional functions. Listed are the functions for the programming options used on the Culligan Medallist Series control. Dip Switch Function...
  • Page 19 English or Metric Press the “STATUS” key. The display will blink “dIP5” for 3 seconds and then show the current status. Toggle between “En” (English units) and “MET” (Metric units) with the “+” or “-” key. 12 or 24 Hour Clock Press the “STATUS”...
  • Page 20 Note: While the programmed menu is locked (“LoC”) all of the programming menu items will display, however only the time of day can be changed. Note: If programming times out, values will not be saved. The “Status” key must be pressed to save values. ® Culligan Medallist Series Water Filters...
  • Page 21 Manual Cycling The Culligan microprocessor can be indexed through the various regeneration steps. For all steps, the cycle numbers do not ® appear, or change, until the motor stops. Press the status button to move past the programming steps until the display is H 00 blank.
  • Page 22 Press the “-” key. The display will blink “daYS” for 3 seconds and then display the number of days since last regeneration. Note: Pressing the “+” key at any time brings back to manual cycling. Pressing “Status” will Exit the programming menu. ® Culligan Medallist Series Water Filters...
  • Page 23: Start-Up Procedure

    Start-up Procedure ® ® Cullar and Cullneu Water Filters • Connect the transformer to a grounded, 120 Volt, 60 Hertz outlet. • Initiate an extra recharge by pressing and holding the “REGEN” button for approximately 3 seconds. • SLOWLY place the bypass valve(s) in the service position. •...
  • Page 24: Operation

    With the blue knob pushed fully inward (knob up against the barrel of the valve, figure 6), water is routed through the water filter. Water may be bypassed around the filter by pushing the red knob fully inward. Avoid “slapping” the valve stem when shifting from one position to another. ® Culligan Medallist Series Water Filters...
  • Page 25 Care and Cleaning Protect the operation and appearance of the water filter by following these precautions: • Do not place heavy objects on top of the control valve cover. • Use only mild soap and warm water to clean the exterior of the unit. Never use harsh abrasive cleaners or compounds which contain acid or bleach.
  • Page 26: Parts List

    Parts List Control Valve ® Culligan Medallist Series Water Filters...
  • Page 27 Item Part No. Description Item Part No. Description 01017638 Control Valve Assembly - Medallist Plus 01014036 Backplate 01014409 Control Valve Assembly - 3/4” Medallist 01013730 Sleeve Eductor Fltr w/ O-rings 01013976 Control Valve Body - Medallist Plus Drive Motor & Bracket Assembly 24v/60hz 00449865 Control Valve Body - 3/4”...
  • Page 28 O-ring (outlet manifold for 1” control) 01009847 Top Strainer, Fine Slot, Medallist Plus 01011195 Top Strainer, Wide Slot, Medallist Plus 01014508 Top Strainer, Fine Slot, Medallist 8” 01014507 Top Strainer, Wide Slot, Medallist 8” * Not Illustrated ® Culligan Medallist Series Water Filters...

Table of Contents