MAINTENANCE
GENERAL VENT MAINTENANCE
Conduct an inspection of the venting system semi-annually.
Recommended areas to inspect as follows:
1)
Check the Venting System for corrosion In areas that are
exposed to the elements. These will appear as rust spots
or streaks, and in extreme cases, holes. These compo¬
nents should be replaced immediately.
2)
Check for evidences of excessive condensation, such as
water droplets forming in the inner liner, and subsequently
dripping out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fittings. It may be
caused by having exterior portions of the system being
exposed to cold weather.
3)
Inspect joints, to verify that no pipe sections or fittings
have been disturbed, and consequently loosened.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn off the
gas valve and allow the unit to cool before opening door to
carefully remove the logs. The pilot light generates enough
heat to burn someone. If for any reason a log should need
replacement, you must use the proper replacement log. The
position of these logs must be as shown In the diagram under
Log installation.
Note: Improper positioning of logs may create carbon
build-up and willalterthe unit's performance which
is not covered under warranty.
GOLD-PLATED DOORS
The 24 carat gold plated finish on the door requires little
maintenance, and need only be cleaned with a damp cloth. DO
NOT use abrasive materials or chemical cleaners, as they may
harmthefinish and void thewarranty. Clean any fingerprints off
before turning the unit on. If the door starts to discolour,
check the gasket seal and replace if necessary.
DOOR GASKET
If the door gasket requires replacement use 7/8" diameter oval
door gasket (Part# 650-920).
LATCH ADJUSTMENT
The door latch may require adjustment as the door gasket
material compresses after a few fires and after glass replace¬
ment. Turn the handle on the adjustable catch to tighten or
loosen the latch.
Catch
GLASS REPLACEMENT
Your Regency stove is supplied with high temperature, 5 mm
Neoceram ceramic glass that will withstand the highest heat
that your unit will produce. In the event that you break your
glass, purchase your replacement from an authorized Regen¬
cy dealer only, and follow the step-by-step instructions for
replacement. Never operate your unit with broken glass.
WARNING: Do not operate appliance with the glass front
removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualified service person.
MITRED DOOR
Removing Glass:
Note: Wearing gloves will protect your hands while han¬
dling glass.
1)
Remove the door from the unit and place on a soft surface
to prevent scratching.
2)
Pull out the door gasket.
3)
Remove the 24 nuts holding the glass retainers in place.
Do not remove the nuts underneath the retainers.