OPERATING INSTRUCTIONS
CONVECTION FAN OPERATION
The fan operates automatically - turn the knob on the side of
the faceplate to adjust to the desired speed. The fan will turn
on as the stove comes up to operating temperature. After the
unit has been turned off and the unit cooled to below a useful
heat output range the fan will shut off automatically.
NORMAL OPERATING SOUNDS OF
GAS APPLIANCES
It Is possible that you will hear some sounds from your gas
appliance. This Is perfectly normal due to the factthat there are
various gauges and types of steel used within your appliance.
Listed below are some examples. All are normal operating
sounds and should not be considered as defects in your
appliance.
Blower:
Regency gas appliances use high tech blowers to push heated
air farther into the room. It is not unusual for the fan to make a
"whirring*' sound when ON. This sound will increase or de¬
crease in volume depending on the speed setting of your fan
speed control.
Burner Tray:
The burner tray is positioned directly under the burner tube(s)
and logs and is made of a different gauge materia! from the rest
of the firebox and body. Therefore, the varying thicknesses of
steel will expand and contract at slightly different rates which
can cause "ticking" and "cracking" sounds. You should also be
aware that as there are temperature changes within the unit
these sounds will likely re-occur. Again, this is normal for steel
fireboxes.
Blower Thermodisc:
When this thermally activated switch turns ON it will create a
small "clicking" sound. This is the switch contacts closing and
is normal.
Pilot Flame:
*
While the pilot flame is on it can make a very slight "whisper"
sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a dull clicking
sound may be audible, ihis is normal operation of a gas
regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will expand and
contract at different rates resulting in some "cracking" and
"ticking" sounds will be heard throughout the cycling process.