Your system is equipped with advanced energy
saving functionality. Depending on the priority
emphasises can be put on energy saving or
comfort level. Several parameters can be selected,
resulting in the optimal balance between energy
consumption and comfort for your particular
application.
Several patterns are available and roughly
explained below. Contact your installer or dealer
for advice or to modify the parameters to the
needs of your building.
Detailed information is given for the installer in the
installation manual. He can help you to realize the
best balance between energy consumption and
comfort.
8.

Maintenance

CAUTION
Pay attention to the fan.
It is dangerous to inspect the unit while the
fan is running.
Be sure to turn off the main switch and to
remove the fuses from the control circuit
located in the outdoor unit.
8.1 Maintenance after a long stop period
(e.g., at the beginning of the season)
• Check and remove everything that might be
blocking inlet and outlet vents of indoor units
and outdoor units.
• Clean air filters and casings of indoor units.
Refer to the operation manual supplied with the
indoor units for details on how to proceed and
make sure to install for details on how to
proceed and make sure to install cleaned air
filters back in the same position.
• Turn on the power at least 6 hours before
operating the unit in order to ensure smoother
operation. As soon as the power is turned on,
the user interface display appears.
(b) Contact your dealer or maintenance person to clean air filters and
casings of the indoor unit. Maintenance tips and procedures for
cleaning are provided in the installation/operation manuals of
dedicated indoor units.
12
01_EN_3P748230-1.indd 12
8.2 Maintenance before a long stop period
(e.g., at the end of the season)
• Let the indoor units run in fan only operation for
about half a day in order to dry the interior of the
units.
Refer to "6.1 Cooling, heating, fan only,
automatic operation and dry operation".
• Turn off the power. The user interface display
disappears.
• Clean air filters and casings of indoor units.
Refer to the operation manual supplied with the
indoor units for details on how to proceed and
make sure to install cleaned air filters back in
the same position.
9.
Symptoms that are not air
conditioner troubles
Following symptoms are not air conditioner troubles:

9.1 The system does not operate

• The air conditioner does not start immediately
after the ON/OFF button on the user interface is
pressed. If the operation lamp lights, the system
is in normal condition. To prevent overloading of
the compressor motor, the air conditioner starts
5 minutes after it is turned ON again in case it
was turned OFF just before.
The same starting delay occurs after the
operation mode selector button was used.
• If "Under Centralized Control" is displayed on
the user interface and pressing the operation
button causes the display to blink for a few
seconds indicating that the central device is
(b)
controlling the unit. The blinking display
indicates that the user interface cannot be used.
• The system does not start immediately after the
power supply is turned on. Wait one minute until
the microcomputer is prepared for operation.

9.2 Cool/Heat cannot be changed over

• When the display shows "
under centralized control), it shows that this is a
slave user interface.
• When the Cool/Heat selector is installed and
the display shows "
centralized control). This is because cool/heat
changeover is controlled by the Cool/Heat
selector. Ask your dealer where the Cool/Heat
selector is installed.
" (changeover
" (changeover under