Remote Unit Information - Paradyne HotWire 7915 User Manual

Standalone e1 sdsl termination unit
Hide thumbs Also See for HotWire 7915:
Table of Contents

Advertisement

Monitoring the Unit

Remote Unit Information

6-4
stats
1
Current 1 minute:
SDSL Errors:
FAW
0
CRC
0
FEBE –
0
Previous 1 minute:
SDSL Errors:
FAW
0
CRC
0
FEBE –
0
stats
Performance statistics have a maximum value of 65,536. If the maximum
value is reached, the statistic resets to zero.
Performance statistics are updated every second.
E1 Errors (CV and FAS) are only displayed for G.703-compatible units that
are operating in framed mode.
Refer to the
Glossary
The same type of information provided for the locally-attached unit (CP or CO)
can also be displayed (but not changed) for the unit on the other side of the
connection (CO or CP).
From a terminal attached to a CP unit, you can display information about the CO
unit by using the STUC Menu options. Similarly, from a terminal attached to a CO
unit, the STUR Menu allows you to display information about the CP unit.
To access the STUC (or STUR) Menu, enter 6 at the Command prompt.
***** STUC Menu *****
1) Board Status
2) Performance Monitor
3) Board Configuration
?) Redisplay this menu
Q) Quit
STUC Command
September 1997
E1 Errors:
CV –
0
FAS –
0
E1 Errors:
CV –
0
FAS –
0
for definitions of the types of errors reported.
7915-A2-GB20-20

Advertisement

Table of Contents
loading

Table of Contents