Paradyne HotWire 7915 User Manual page 23

Standalone e1 sdsl termination unit
Hide thumbs Also See for HotWire 7915:
Table of Contents

Advertisement

7915-A2-GB20-20
The Board Configuration menu varies slightly for CO units that are connected to
V.35/V.11-compatible units at a sub-E1 rate (less than 2048 Kbps). The difference
is in Option 3, which changes from Framed/Unframed to selection of a Starting
Time Slot. (Refer to
Table 4-1
follows:
Command
3
Board Configuration:
–––––––––––––––––––
1) SDSL Card Type
SDSL Rate Type
2) E1 Line Encode
3) Starting Time Slot
Payload rate
SDSL FW Rev
Globespan FW Rev
CP Serial #
–––––––––––––––––––––––––––––––––––––––––––––––––––––––
1–3)
Board Configuration
4)
Switchpack Definitions
?)
Prints Board Configuration and this menu
Q)
Quit
Config
The SDSL rate type, firmware revision numbers, and the serial number displayed
on the Board Configuration screen cannot be changed. The payload rate is set at
the V.35/V.11-compatible unit.
Switchpack Definitions, option 4 on the Config menu, displays the switchpack
settings to use when changing configuration changes manually. Refer to
Displaying Switchpack Definitions
Possible values for each option are listed in
September 1997
Customizing G.703-Compatible Units
for more information.) The menu appears as
– CO
– E1
– HDB3
– 1
– 512 Kbps (8x64)
– 02
– 1.07
– 088165
on page 4-6.
Table
4-1.
4-3

Advertisement

Table of Contents
loading

Table of Contents