COMSPHERE 3821Plus Modem
5. Press the
key until the appropriate factory
preset appears on the LCD, and press the
corresponding function key to select your choice.
6. Choose Function appears and displays the Edit and
Save functions.
7. Press the F3 key (Save) to save the new factory
preset configuration to one of three configuration
areas, Active (Saved), Customer 1, or
Customer 2.
(These three configuration areas are nonvolatile
memory locations. Active (Saved) contains the
most recently saved changes to any configuration
options. In the event of power loss, the modem
retrieves these configuration options. Customer 1
and Customer 2 are user-defined configuration
areas.)
The LCD now displays Sav EditArea to.
8. Press the
key until the appropriate
configuration area appears on the LCD, then press
the corresponding function key to select your
choice. (Saving configuration options to the Active
(Saved) configuration area automatically saves
them to the Active (Operating) configuration area.)
The LCD displays Command Complete.
9. The modem is now configured with the selected
factory template. Press the
Top-Level menu.
Refer to
Configure Branch
information regarding default factory configuration
options.
2-6
key to return to the
in Chapter 3 for more
February 1998
Selecting Configurations Using
AT Commands
When using AT commands, the following criteria must
be met:
Make sure the asynchronous DTE's communication
software is configured for 10-bit character format
(for example, 8 data bits, no parity, and 1 stop bit).
Make sure the DTE (RS-232D) cable is attached to
the DTE connector at the rear of the COMSPHERE
3000 Series Carrier, and to the correct serial
communications port on the asynchronous DTE.
On initial power-up, the modem is in Command
mode. To verify that the modem is connected and
functioning properly, enter the following:
TYPE:
AT
PRESS:
Return (Enter)
The screen displays OK.
If the modem does not return OK, refer to Appendix C,
Troubleshooting.
NOTE
If you have already changed the
factory preset configuration you
may have lost AT command
control. To regain AT command
control, select, via the SDCP, the
Async Dial factory preset
configuration as described earlier
in Selecting Configurations Using
the SDCP.