VARIABLE DRIVE CONFIGURATION
1- Operating principle :
The variable drive is used for one of its most basic functions, namely overspeed operating.
Thanks to the types of fan curve used, we can make a fan operate at a speed from 70 to 87 Hz.
With conventional starting up, it would not be possible to operate it above 50 Hz (electrical system frequency).
Thus, we can operate at overspeed while keeping the system vacuum constant.
2- Settings :
Operating front :
-18
Reference
Description
% indicator
0
Hz indicator
RUN indicator
1
PRG indicator
MON indicator
2
MODE key
3
ENT enter key
4
STOP stop key
RUN key
5
RUN indicator
LOC REM local/remote key
6
LOC REM key indicator
Down key
7
Up key
Indicators of keys
Reference
Description
1
Front panel
2
Charge indicator
3
Locked position indicator
4
Panel locking screw
5
Unlocked position indicator
8695 8420 / A
Comments
Goes on when a numerical value is
displayed as a percentage.
Goes on when a numerical value is
displayed in Hertz.
Goes on when an activation control is
triggered.
Goes on when the variable drive is in
setup mode and flashes when it is in
AUF mode.
Goes on when the variable drive is in
monitoring mode.
Displays the operating frequency,
settings and reasons for errors.
Each press on the key when the Run
indicator is on slows the device down
till it stops completely.
If you press this key when the Run
indicator is on, the variable drive starts.
Goes on when you press the RUN key.
Switches between the 2 modes.
Goes on when the Local mode is
activated
You can modify the frequency if it is on
Comments
Guard panel
Indicates that voltage is still present in
the variable drive
Panel locked in this position
Screw for locking the panel
Panel unlocked in this position
CCHD