6. SYSTEM MONITOR
This menu is used to display A/D conversion value
of the microprocessor which detects panel keys and
protection functions by using the sub-menu.
*
Numeric values in the figure are given as reference
only.
6-1. ILLUMINATION SENSOR
Not for service.
6-2. MODEL
Model name of this unit detection:
The voltage at 97 pin (MODEL) of microprocessor
is displayed in hexadecimal notation.
(Reference voltage: 3.3 V=FF)
6-3. DESTINATION
Destination of this unit detection:
The voltage at 90 pin (DEST) of microprocessor
is displayed in hexadecimal notation.
(Reference voltage: 3.3 V=FF)
Display / 表示
Destination / 仕向け先
6-4. PS1 PROTECTION
Power supply voltage detection (+VP, +34V):
The voltage at 93 pin (PS1_PRT) of microprocessor
is displayed in hexadecimal notation.
Normal value: 58 to 8C
(Reference voltage: 3.3 V=FF)
*
If PS1 becomes out of the normal value range,
the protection function works to turn off the
power.
34
6 - 1   L U M I : 0 0
6 - 2   M O D E L : 7 E
Display / 表示
0 – 10
Model name / モデル名
MCR-B043D
6 - 3   D E S T : 3 F
0 – 10
11 – 30
31 – 53
U
K
J
6 - 4   P S 1 : 7 2
6.  SYSTEM MONITOR
パネルキー、プロテクションなどを検出しているマ
イコンの A/D 変換値が、サブメニューで表示されま
す。
※  図中の数値は参考例です。
6-1.  ILLUMINATION SENSOR
サービスでは使用しません。
6-2.  MODEL
本機のモデル名の検出:
マイコンの 97 ピン(MODEL)の電圧値が 16 進
数で表示されます。
(基準電圧:3.3 V=FF)
7A – 9d
MCR-B043
6-3.  DESTINATION
本機の仕向け先の検出:
マイコンの 90 ピン(DEST)の電圧値が 16 進数
で表示されます。
(基準電圧:3.3 V=FF)
54 – 79
7A – 9d
9E – c1
L, V
G
6-4.  PS1 PROTECTION
電源電圧の検出(+VP、+34V) :
マイコンの 93 ピン(PS1̲PRT)の電圧値が 16
進数で表示されます。
正常値:   58 〜 8C
(基準電圧:3.3 V=FF)
※  PS1 が正常値を外れるとプロテクションが働
き、電源が切れます。
c2 – E9
EA – FF
A
B