3. Removal of Loader Mechanism Unit (Fig. 2)
a.
Using the anti-static soldering iron, short between
terminals on the optical pick-up unit P.C.B. included
in the loader mechanism unit.
Note: After you have finished repairing, remove
the solder from the short-circuit location
with the antistatic soldering iron.
b. Remove 4 screws ( ⑦ ).
c.
Remove CN503 of the loader mechanism unit.
d. Unlock and remove CB301.
e.
Remove the loader mechanism unit.
4. Removal of Power Supply Module (Fig. 2)
a.
Remove 5 screws ( ⑧ ).
b. Remove CON1 and CON2.
c.
Remove the power supply module together with the
support.
P.C.B. of optical pick-up unit
オプティカルピックアップユニッ トの P.C.B.
The point that short-circuits with a solder
はんだでシ ョートする箇所
Solder
はんだ
P.C.B.
Optical pickup unit
*
When replacing the loader mechanism unit with a new one,
reattach the LASER CAUTION label from the old unit to the
new unit.
※ 新しいローダーメカユニッ トに交換する場合、
LASER CAUTION ラベルを貼り直してくださ
い。
3. ローダーメカユニットの外し方(Fig. 2)
a. ローダーメカユニット内にあるオプティカルピック
b. ⑦ のネジ 4 本を外します。
c. ローダーメカユニットの CN503 を外します。
d. ロックを外し、CB301 を外します。
e. ローダーメカユニットを外します。
4. 電源モジュールの外し方(Fig. 2)
a. ⑧ のネジ 5 本を外します。
b. CON1、CON2 を外します。
c. 電源モジュールをサポートと一緒に外します。
Loader mechanism unit
ローダーメカユニッ ト
⑦
CN503
CB301
Unlocked
Locked
Flexible flat cable
カード電線
Fig. 2
MCR-B043/MCR-B043D/NS-BP83
アップユニットの P.C.B. 上の端子間を静電気対策はん
だこてを使用してショートします。
注意: 修理終了時は、静電気対策はんだこてを使
用してショート箇所からはんだを除去しま
す。
Power supply module
電源モジュール
CON2
⑦
Support
サポー ト
⑧
CB301
CON1
⑧
⑧
MAIN (1) P.C.B.
15