● Preparation and precautions
•
Download the firmware downloader program and
the latest firmware from the specified download
source to the same folder of the PC.
•
Prepare the above specified RS-232C cross cable.
•
While writing the firmware, keep the other application
software on the PC closed.
It is also recommended to keep the software on
the task tray closed as well.
● Connection
*
Disconnect the power cable of this unit from the
AC outlet.
•
Set the switches on RS-232C conversion adaptor
as shown below. (Fig. 1)
Switches Setting / スイッチ設定
Microprocessor type
T type
R type
•
Connect the serial port (RS-232C) of the PC to
the writing port (CB107 on MAIN (1) P.C.B.) of this
unit as shown below. (Fig. 2)
PC
Serial port (RS-232C)
シリアルポート (RS-232C)
RS-232C cross cable
RS-232C クロスケーブル
T
SW7
Firmware to be updated
Microprocessor firmware writing mode
マイコンファームウェア書き込みモード
Self-diagnostic function mode
ダイアグモード
Microprocessor firmware writing mode
マイコンファームウェア書き込みモード
Self-diagnostic function mode
ダイアグモード
RS-232C conversion adaptor
RS-232C 変換アダプター
● 準備と注意
・ 指定のダウンロード先から、ファームウェア書き
込み用プログラムと最新のファームウェアを、 PC
の同じフォルダにダウンロードしてください。
・ RS-232C クロスケーブルは必ず上記仕様のものを
用意してください。
・ 書き込み時は、PC 上の他のアプリケーションソ
フトは閉じてください。
さらに、タスクトレイ上にあるソフトも閉じてお
くことを推奨します。
● 接続
※ 本機の電源コードを AC コンセントから抜きます。
・ RS-232C 変換アダプターのスイッチを下記のよう
に設定します。 (Fig. 1)
DSP ucom T
ucom DSP R
RS-232C conversion adaptor
RS-232C 変換アダプター
R
SW4
Fig. 1
・ 本 機 の 書 き 込 み 用 ポ ー ト(MAIN(1)P.C.B. の
CB107)と PC のシリアルポート (RS-232C)を下
記のように接続します。 (Fig. 2)
Rear view of this unit / 本機の後面
Writing port / 書き込みポー ト
(CB107 on MAIN (1) P.C.B.)
Flexible flat cable (9P)
カード電線 (9P)
Fig. 2
MCR-B043/MCR-B043D/NS-BP83
SW7
SW4
19