Lincoln Electric DLF-82 Operator's Manual page 25

Table of Contents

Advertisement

DLF-82
®
Wire Feed Speed Calibration:
This is used to calibrate the feeder's wfs meter to a known
calibrated WFS meter. To calibrate the wire feed speed, before
entering the set-up menu:
- Set the display to desired WFS (example: 400 IPM)
- Measure the actual WFS (example: 405 IPM)
While in the Advanced Setup Menu, adjust the calibration factor
as follows:
* Actual WFS/ Set WFS = Calibration Factor
* Example: 405/400 = 1.01
Password Setting / Enable:
A resettable 4 digit password can be set from the Advanced
Setup Menu. Once in the Advanced Setup Menu navigate to
"Password" by default it is Off. When the bottom knob is
using the bottom left knob. When the decided number is set
press the bottom left knob again to move one digit to the
right. Follow the same procedure described above to set this
digit and continue to do so for the remaining two digits.
Once all four digits have been selected the next knob press will
save the password and where the four digit password was on
the right side of the bottom display will then be replaced with
"****". This means that the password has been successfully set
and in order to modify the below Setup Menu Items, it will need
to be entered:
- Wire Feed Speed Limits Settings
- Voltage or Trim Limits Settings
- Arc control limits settings
- Process Selection Lockout
- Number of Memories
- Memory Save Enable
Software Version:
The current software version number as well as the checksums
are displayed on the "WD/UI" item of the Advanced Setup
Menu. This menu item is read only and may be useful for
troubleshooting purposes. Pushing the bottom encoder will
scroll through the different software revisions of different printed
circuit boards in the system.
- WD/UI contains information about the DLF-82's Control
Board.
- WCtl contains information about the Power Source's
Control/Switch boards.
- WTbl contains information abou the weld table version
number.
Factory Reset:
Factory Reset can be initiated to return all settings to their
default values. In addition to resetting stored memories and
procedures to their default values many other settings are reset.
This list includes, but is not limited to:
- All procedures setpoints (WFS, voltage/trim)
- All previously set limits (Arc Control, Trim, WFS etc.)
- All calibration data
- All stored True Energy Information
- Password is disabled
Arc Time Display Enable:
"Arc Time" in the advanced setup menu is Off by default. If it is
enabled then the User's Arc Time will be displayed for 5 seconds
after the system mapping is complete. When viewed from the
advanced setup menu the cumulative arc time and the user arc
time will be displayed on the top line. The user arc time can be
reset by pressing and holding the bottom knob for 3 seconds
and following the prompts.
Test Modes Enable:
"Test Modes" in the Advanced Setup Menu are set to N by
default. When enabled and set to Y, they are populated at the
end of the process selection screen. They include CC, CV, CP
and others and are typically not used during normal operation.
To disable them, navigate back to the Advanced Setup Menu
and select N and push the bottom left knob.
System Test:
Once "System Test" is enabled all of the LEDs should be
illuminated. Pushing the bottom left knob will enter an
encoder test that will use the displays to provide the user
with a readout of how many counts the encoders have
registered. This can be useful in determining if any of the
encoders are damaged. Pushing the bottom knob a second
time will navigate back to the Advanced Setup Menu and
return the "System Test" to N.
B-12