DLF-82
®
DIGITAL METER OPERATION - WHILE IDLE
The left display shows the preset wire feed speed while the right
display shows the preset voltage or trim when it is connected to a
power source that supports the DLF-82 (see Figure B.1). It will
display dashes when connected to an incompatible power source
(the lower display will show "Error 262"). If the power source's
mode selection is not in ArcLink® Mode, then the lower display
will show "Sleep Mode".
Active procedure (if procedure B is selected)
WIRE FEED SPEED/AMPS
PROCESS SELECT
DIGITAL METER OPERATION - WHILE WELDING
The left display shows amps or WFS based on the selection in
the settings menu (the corresponding LED will be illuminated).
The right display shows Voltage or Trim, depending on whether
pulse mode is selected or not.
VOLTAGE OR TRIM PRESET
DIGITAL METER OPERATION - AFTER WELDING
The display continues to hold the value of the amperage
completion of each weld. The corresponding LEDs (for
rate to identify these as "Look Back" values. Turning any
of the 3 knobs will cause the displays to show preset
information.
If True Energy display is enabled, and the connected
power source supports it, the bottom display will show
the accumilated energy in kilo joules (KJ) and arc time in
seconds for the duration of each weld. The values for
energy and arc time are stored for the last 20 welds and
can be accessed through the advanced setup menu.
True Energy is available only if the power source
supports it. As of publication date no Flextecs or
Vantages support this feature.
-