DLF-82
®
Setup Menu
The Setup Menu is the last item choice in the Settings Menu.
When "Enter Setup Menu" is displayed (and blinking) pressing
the bottom knob will enter the setup menu.
A press of the bottom right push button exits the setup menu
and returns to the top of the settings menu.
A short press of the bottom knob will select the menu item
that is blinking. After the press, the value to be set will blink.
Rotating the bottom encoder knob will change the selected
value.
Pressing the bottom encoder push button again will store the
value that has been set.
The "Setup Menu" items are:
True Energy Logs (if supported by the power source)
True Energy Display Setting (if power source has this
capacity) (default=disabled)
Metric/Imperial WFS display settings (default=Imperial)
Arc Current or Actual WFS display during welding
(default=Amps)
Trigger selection of memories (default=inactive)
WFS Limits (default=disabled)
Volts Limits (default=disabled)
Arc control Limits (default=disabled)
Trim Display Setting in Trim versus Volts Display Setting
(default=trim)
Process Selection Lockout (default=unlocked)
Number of Memories (default=4)
Memory Save Enable (default=active)
True Energy Logs
True Energy Logs allow a user to look back on the 20 most recent
item in the setup menu. They will be visible if the power source
being used supports them.
default. In order to view the Logs press the bottom knob and turn
it to change the option to "Y". Once the encoder button is pushed
with "Y" selected the most recent weld information will be
displayed. Turning the bottom knob allows up to the twentieth
weld's information to be displayed.
True Energy Display Setting:
When True Energy is set to "On" the running total of energy [kJ]
the weld is completed it will be available to view in the True
Energy Logs.
Metric/Imperial WFS display settings:
The wire feed speed settings can be viewed in Metric or Imperial
Units by selecting either "Imperial" or "Metric" in the "Units"
section of the Setup Menu. By default "Imperial" is selected.
Arc Current or Actual WFS during welding:
With "Display" selected (blinking) in the Setup Menu, pressing
the bottom encoder push button will allow the top left digital
display to show Arc Current ("Amps") or WFS ("WFS"). By
default Arc Current will be displayed.
Trigger Selection of Memories:
The Trigger Selection of Memories is used to scroll through the
available memories using just the weld gun. The option is "Trig
Mem" in the Setup Menu and is by default set to Inactive. Once
Active, gun trigger pulls can be used to load memories one
through four into the active procedure when not welding. When
memory at its current setting. Each subsequent trigger open
and close will cycle through memory 1,2,3, and 4 in ascending
order.
Setting WFS Limits:
With WFS Limits selected (blinking) in the Setup Menu, pressing
the bottom knob will cycle through the Low Limits (LO) and High
Limits (HI). By default they are both Off.
To adjust the Low Limits: Push the bottom knob until LO is
blinking. Once blinking, turning the encoder clockwise will
increase the limit and counter-clockwise will decrease the limit
with the lowest value being "Off".
To adjust the High Limits: Push the bottom knob until HI is
blinking. Once blinking, turning the encoder clockwise will
increase the limit and counter-clockwise will decrease the limit
with the lowest value being "Off".
These settings will be those associated with the active procedure.
To disable any of the limits, turn the associated knob clockwise
until the display shows "OFF". The values will be set as they are
adjusted. The limits settings are stored independently for each
memory location.
-