Option Screens

NOTE: See F
. 21 on page 27 for a map of the Option
IG
Screens. Detailed screen descriptions follow.
NOTE: Each screen displays the current screen number
and the total number of screens in the group.
Option Screen 1
F
. 29. Option Screen 1
IG
Flush Volume Check
This field only appears if Solvent Monitor is set to
"Meter" in Configure Screen 5, page 30.
If set to "On", Minimum Flush Volume will appear in Rec-
ipe Setup Screen 2, page 36.
Flush and Fill Input
If set to "Global", Color/Catalyst Purge and Color/Cata-
lyst Fill are added to Advanced Setup Screen 1, page
33. Advanced Setup Screen 2, 3, and 5 are added.
See pages 33-34.
If set to "Recipe", Color/Catalyst Purge and Color/Cata-
lyst Fill are added to Recipe Setup Screen 2, page 36.
Recipe Setup Screen 3, 4, and 7 are added. See
pages 37-38.
K-Factor Input
If set to "Global," Advanced Setup Screen 4, page 34 is
added.
If set to "Recipe," Recipe Setup Screen 5, page 38, is
added.
Minimum Material Fill Volume
Enter 0-9999 cc.
312776B
Verification Screen
F
. 30. Verification Screen
IG
Verification
This screen appears if Flush and Fill Input or K-Factor
Input are changed from "Recipe" to "Global" in Option
Screen 1.
Option Screen 2
F
. 31. Option Screen 2
IG
Auto Dump
If the auto dump feature is being used, set to "On". Once
the auto dump is enabled, the gun flush box is enabled
and the potlife alarm is active for 2 minutes, the system
will automatically flush out the old material.
Flow Rate Monitor
If set to "On," Recipe Setup Screen 6 on page 38 is
added, enabling setting of high and low flow limits.
If set to "Off," flow rate monitoring is disabled and Rec-
ipe Setup Screen 6 on page 38 will not appear.
Setup Mode
31