Alarms and Warnings

NOTICE
Do not use the fluid in the line that was dispensed off
ratio as it may not cure properly.

System Alarms

System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
A red LED illuminates steadily or blinks on the Booth
Control.
Booth Control displays an alarm E-Code, E-1 to
E-27. See F
. 87.
IG
Alarm sounds.
Status bar on the EasyKey Display shows the alarm
E-Code with a description (see Table 10).
Alarm Indicator (red)
Recipe Indicator (green)
F
. 87. Booth Control
IG

System Warnings

Table 10 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
312776B
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 10. If you forget
which E-Code occurred, use the Alarms Screens (page
22) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 11. Many alarms can be
cleared by simply pressing the Alarm Reset
Code Description
E-1
E-2
E-3
Display
E-4
E-5
E-6
E-7
E-8
E-9
E-10
E-11
E-12
E-13
E-14
E-15
E-16
TI11614A
E-17
E-18
E-20
E-21
E-22
E-23
E-24
E-25
E-26
E-27
Table 10: System Alarm/Warning Codes
Communication Error Alarm
Potlife Alarm
Ratio High Alarm
Ratio Low Alarm
Overdose A/B Dose Too Short Alarm
Overdose B/A Dose Too Short Alarm
Dose Time A Alarm
Dose Time B Alarm
Mix in Setup Alarm
Remote Stop Alarm
Purge Volume Alarm
CAN Network Communication Error
Alarm
High Flow Alarm
Low Flow Alarm
System Idle Warning
Setup Change Warning
Power On Warning
Defaults Loaded Warning
Purge Initiate Alarm
Material Fill Alarm
Tank A Low Alarm
Tank B Low Alarm
Tank S Low Alarm
Auto Dump Complete Alarm
Color/Catalyst Purge Alarm
Color/Catalyst Fill Alarm
Alarms and Warnings
key.
Details
Page 74
Page 74
Page 75
Page 76
Page 77
Page 77
Page 78
Page 78
Page 79
Page 79
Page 79
Page 79
Page 79
Page 79
Page 80
Page 80
Page 80
Page 80
Page 80
Page 81
Page 81
Page 81
Page 81
Page 81
Page 81
Page 81
73

Advertisement

Table of Contents
loading

Table of Contents