a) Connect the cables (1) to a cable connector (2).
b) Connect the roof air conditioner with the power supply.
c) Connect the grounding cable to the vehicle's grounding system.
9.
Only mechanical models: Connect the cable between the external unit and the air box diffuser.
a) Pull out the filter slightly to create a gap for the communication cable (3).
b) Feed the cable through the gap and locate the wire in the opening.
c) Connect the communication 6-pin plug into the socket on the side of the display in the ADB. Ensure that the
cable is located into the small opening away from the filter area.
d) Secure excess cable into the holders.
10. Only fixed-speed and inverter models: Connect the communication cable.
a) Pull out the filter slightly to create a gap for the communication cable (4).
b) Feed the communication cable through the gap and locate the wire in the opening.
c) Connect the communication 4-pin plug into the socket on the side of the display in the ADB. Ensure that the
cable is located into the small opening away from the filter area.
d) Secure excess cable into the holders.
11. Stack the duct sections and place against the roof thickness.