Reconfiguring Trigger Hold For 4T And Mini Logic Control - Miller Syncrowave 250 DX Technical Manual

Hide thumbs Also See for Syncrowave 250 DX:
Table of Contents

Advertisement

4-7. Reconfiguring Trigger Hold For 4T And Mini Logic Control

1
Output Control
2
Power Switch
To reconfigure Trigger Hold, turn Off
power, push and hold Output control
button and turn On power switch.
Hold button for approximately 7 sec-
onds (or until software version num-
ber _ _ _ _ _ _-_clears, and meters
display [SEL] [H−2].
Press Output control button to
change functions. Active function will
be displayed on amperage (bottom)
meter.
3
Meter Displays
Meter displays for the different func-
tions will be as shown.
Press torch trigger or turn power Off
to save setting.
Proceed to Section 4-6 for 4T Opera-
tion.
Proceed to Section 4-6 for Mini Logic
operation.
Proceed to Section 4-6 for 4T Mo-
mentary operation.
NOTE: These features are only
available when optional Sequencer
is installed.
SEL
= 4T Momentary
(See Section 4-6)
H-4E
TM-359 Page 36
1
SEL
= 4T
(See Section 4-6)
H−4
Front Panel
SEL
= Mini Logic
(See Section 4-6)
H4L
2
SEL
H−2
3
Syncrowave 250 DX

Advertisement

Table of Contents
loading

Table of Contents