Miller Syncrowave 250 DX Technical Manual page 73

Hide thumbs Also See for Syncrowave 250 DX:
Table of Contents

Advertisement

gnd
E. DC Open-Circuit Voltage, Amperage Adjust-
ment Control At Max, Arc/Balance Control At
Balanced Position, Waveform May Not Be
Stable
gnd
G. SCR Gate Pulses With Respect To Cathode
At 10 Volts AC, 150 Amperes (Resistive
Load)
Syncrowave 250 DX
5 ms 50 V
gnd
F. 10 Volts DC, 150 Amperes, Arc/Balance Con-
5 ms 1 V
trol At Balanced Position (Resistive Load)
Test Equipment Needed:
5 ms 5 V
TM-359 Page 69